Accessories
A
Mounting plate
D
Insulation tape
Fixing screw for remote
G
controller holder 1/8" × 13/16"
(M3 × 20mm)
K
Installation manual
Choosing an Installation Site
• Before choosing the installation site, obtain user approval.
1�
Indoor unit
The indoor unit should be positioned in a place where:
1) the restrictions on installation requirements specified in "Indoor Unit Installation Drawings" on page 4 are met,
2) both the air inlet and air outlet are unobstructed,
3) the unit is not exposed to direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten the indoor unit service life),
6) cool/warm air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may affect the remote
controller range,
8) the unit is at least 3.3ft (1m) away from any television or radio set (the unit may cause interference with the picture or
sound),
9) no laundry equipment is nearby.
2�
Wireless remote controller
Turn on all the fluorescent lamps in the room, if any, and find a location where remote controller signals are properly
received by the indoor unit (within 23ft (7m)).
3
Titanium apatite photocatalytic
1
B
air-purifying filter
2
E
Wireless remote controller
Dry battery AAA. LR03
2
H
(alkaline)
1
2
C
Drain hose
1
F
Remote controller holder
2
J
Operation manual
1
1
1
■
English