BED PROGRAMMING
WET TABLE
001
11
/
A blue backlit key indicates the programme selected. The display shows the preset temperature (with an
accuracy of 1°C) and cycle time (minutes and seconds).
Users can change the preset temperature and cycle time by pressing the appropriate keys within the range
allowed, verifying their value on the display.
Each change of the preset values of a cycle makes the backlighting of the relevant PROG key go from blue to
white.
When the steam cycle is OFF, users can associate the cycle temperature selected to one of the PROG keys by
pressing the relevant PROG key for at least 3 seconds. When the association is stored, the key backlighting will
become blue (memory function). A cycle is started by pressing the START/STOP key. When the cycle is on, this
key is backlit blue. The display shows the bed temperature and the time left before the end of the cycle.
When the cycle is on, users can change the preset temperature and time or select another programme. By
pressing the key + or – TEMPERATURE, the display shows the set temperature and users can change its value.
The display shows the bed temperature again 5 seconds after keys are last pressed. A cycle stops when the
set time has run out or by pressing the START/STOP key. In both cases, temperature and time (or time only)
are reset at their original value (that is that of the selected programme). When the steam cycle has been off
for 1 hour, the system automatically starts draining and refilling the boiler in order to delay the formation of
deposits.
CHROMOTHERAPY FUNCTION
The bed is equipped with 4 RGB LED lights that operate in automatic sequence.
The chrome function is activated when the button is pressed and it has blue backlighting. After this a series
of default colors are turned on. A short press stops the color sequence present at the time; the backlight turns
into solid blue; another short press causes a color change. The CROMO function can be terminated with a long
press of the button CROMO. The backlight turns into white.