The Basin - Liberty Pumps Pro-Serie Manual De Instalación

Ocultar thumbs Ver también para Pro-Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Pump and Alarm floats are pre-set on the
Was your system sized by a professional? Minimum fluid flows are required in sewage applications. Consult Factory for proper pump
sizing prior to installation.
®
QuickTree
Technology: The Pro-Series by Liberty Pumps features new QuickTree
system is located under a separate access cover for ease of maintenance and service. Floats for both pump activation and alarm (if
equipped) are mounted on a stainless steel tree (rod), separate from the pump. There is no need to disconnect plumbing or remove the
pump to inspect service or replace floats. QuickTree
adjusted.

2. The Basin

The Pro-Series Systems features a clear disposable construction cover designed to protect the system during rough-in and masonry
work. The protective cover should remain in place until finish plumbing; however, can be removed and reinstalled if required. The
cover is snapped into the threaded ports of the discharge and vent. To remove the clear cover, simply pull upward disengaging it from
the discharge and vent holes.
In Ground Installation of Pro-Series Basins
A.
Excavation: Excavate the hole as small as possible, with a minimum recommended 8" diametrical clearance around the tank.
Never place the basin directly in contact with rocks or other sharp objects. Place only fine, 1/8" to 3/4" pea gravel or 1/8" to 1/2"
washed, crushed stone as bedding between the basin and the hole walls. Do not use sand or native soil as backfill. Properly
compact underneath the basin to provide a solid, level base that can support the weight of the filled basin. It is recommended that
the top lip of the basin be level with the finished floor.
B.
Initial Backfill: Only fine, 1/8" to 3/4" pea gravel or 1/8" to 1/2" washed, crushed stone should be used around the bottom of the
basin to hold it in place. Do not use sand or native soil as backfill. Make the inlet connection as required for your basin.
C.
Inlet Connection: The Liberty P370 and P380 series basins have a 4" inlet molded to the side of the tank. This inlet is sized to
accept a 4" no-hub type coupling. Connect the gravity drainage line from the fixtures to this hub.
D.
Final Backfill: Large rocks, clods, and foreign objects should be kept out of the backfill material. Only fine, 1/4" to 3/4" pea
gravel, or 1/8" to 1/2" washed, crushed stone is recommended. Do not use sand or native soil as backfill. Mound the backfill
slightly and allow for natural settling. Provide access to the basin cover for maintenance and service.
Dimensional Data
QuickTree®
Do not exert heavy pressure or run heavy equipment on the backfill material as this could cause the
tank to collapse.
Pro380-Series
©Copyright 2008 Liberty Pumps Inc. All rights reserved
system at proper operating levels. Do not adjust floats.
®
floats are preset at the factory for optimum operating levels and should not be
®
float system technology. The QuickTree
Pro370-Series
®
3

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Pro370-seriePro380-serie

Tabla de contenido