7.
MOST FREQUENT ERRORS
ERROR
When the centre is powered
1
by 230 VAC, any led light up.
The right red led flashes
2
quickly.
(Zoning type installation)
5 min after switching the
centre on, the zone leds
3
flashes in all zones and all
grilles are closed.
Some of the zone led flashes
4
and the damper in this zone
is closed.
When the damper should
open close
5
(And vice versa).
One of the dampers does
6
not work.
All of the dampers work
properly but the air
7
conditioning equipment does
not work.
The equipment switches on
and of with the MASTER at a
8
standstill or some zones
close or open without any
signal from the thermostat.
TECHNICAL CHARACTERISTICS:
Control board (receiver)
Power: 230 VAC, 50/60 Hz.
Power consumption: 4 VA
2 Relay outputs. Maximum current load: 6 A .Cos
Average scope: 50 m in free field. 20 m in the habitat.
External aiming antenna.
Size (mm): 105 x 90 x 60
Carrier frequency (ISM Band, as per I-ETS 300-220 standard):
434.33 MHz (Optional: 433.92 MHz)
Operating cycle <10%
Receiver. Class III
Protection level: IP 20
Electric shock insulation Clase II.
Operating temperature: 0 ºC a 55ºC.
Storage temperature:: -10 ºC a 60 ºC.
Hereby MADEL ATD decalres that the KSP (control board + thermostat) is in compliance with the essential requirements and other relevant provisions
of Directive 1999/5/CE.
http://www.madel.com/eng/pdf/Zoningconformidadksp.pdf
INDICADOR
CAUSA
Lack of
voltage
Sensor error
Incorrect
configuration
communication
Motors badly
connected
Zone regulator
connection
Air conditioning
equipment badly
connected
Interference with
neighbouring
installations
Thermostat (transmiter)
Power: 2 x 1.5 V LR06 AA batteries (supplied). Average
=1
Battery wear indicator.
Carrier frequency (ISM Band, as per I-ETS 300-220 standard):
Average scope: 50 m in free field. 20 m in the habitat.
Size (mm) (mm): 112 x 71 x 19.
Operating temperature: 0 ºC a 55ºC.
Storage temperature:: -10 ºC a 60 ºC..
Wall attachment using screws (supplied)
Protection level: IP 20
ECO mode (ordered temp. variation of 3ºC)
SOLUCIÓN
Check that voltage reaches the
centre (230 VAC 10%).
Connect the sound or leave the
resistance
default.
Check thermostat configuration.
Antenna not receiving.
position.
The zone is badly configured in the
Bad
thermostat SETUP.
Interference in the communication.
Modify thermostat location.
Thermostat battery low
Check the motor connection.
Polarity (black -, red +)
Check the motor connection.
Polarity (black -, red +)
Check that the regulator is not
obstructed.
Check the Sw1 configuration of the
control centre depending on the
machine type.
Check the equipment connection
to the board.
Check that there are no two
thermostats
configuration.
Check whether there is some other
Zoning System with the same
series number installed in the
neighbouring households (0.03%
probability)
autonomy 1 year (or more).
434.33 MHz (Optional: 433.92 MHz)
ENGLISH
which is
wired for
Modify
with
the
same
V. 03.12