are opened and/or when they are closed.
By default, LCD5501Z keypads are pro-
grammed to sound door chimes on both
zone openings and closings.
To change the door chime opening/clos-
ing settings, at each LCD5501Z keypad:
1.
Enter [*][8][Installer's code]
2.
Enter [000] to go to keypad program-
ming
3.
Enter section [6].
4.
To turn the options on or off, press [6]
or [7]:
[6] ON =Door Chime Enabled for Zone
Openings
OFF =Door Chime Disabled for Zone
Openings
[7] ON =Door Chime Enabled for Zone
Closings
OFF =Door Chime Disabled for Zone
Closings
5.
When you are finished, press [#] to ex-
it.

Door Chime Sounds

You can program the LCD5501Z keypad
to make different door chime sounds for
individual zones, or groups of zones.
Each LCD5501Z keypad can make any
of four door chime sounds for each zone
that triggers the door chime:
•4 quick beeps (default sound)
•'Bing – Bing' tone
•'Ding – Dong' tone
•'Alarm' tone
NOTE: For a zone to be able to trigger the
door chime sound, the Door Chime zone at-
tribute must also be enabled in the control pan-
el programming. Please see your control panel
Installation Manual.
To change the door chime sounds:
1.
Enter [*][8][Installer's code].
2.
Enter [*] to go to door chime sound
programming.
3.
Enter a 2-digit number for the zone
you want to program [01] - [64].
4.
Turn one of the following options on by
pressing [1], [2], [3], or [4]:
[1]4 quick beeps (default sound)
[2]'Bing – Bing' tone
[3]'Ding – Dong' tone
[4]'Alarm' tone
NOTE: Make sure that only one of the above
options is turned on. If more than one is on,
the keypad will sound the first option that is
enabled. If none of the options are selected, the
keypad will not make any sound when the zone
is opened or closed.
5.
To program the door chime sound for
another zone, repeat steps 3 and 4.
6.
When you are finished programming
the door chime sounds, press [#] to
exit.

Zone Input/PGM Output Option

The LCD5501Z 'Z/P' terminal can be pro-
grammed to support one zone input (de-
fault) or one PGM output. To change this
option:
1.
Enter [*][8] [Installer Code].
2.
Enter [000] to go to Keypad Program-
ming.
3.
Enter section [6].
4.
Turn the option on or off by pressing
[8].
If Option 8 is ON, the 'Z/P' terminal is an
output.
If Option 8 is OFF, the 'Z/P' terminal is an
input.

Programming the PGM Number

In order to assign a PGM output to the "Z/
P" terminal, a PGM number must be en-
tered. This number has to be one of the
PGM outputs that can be programmed in
the panel.
1.
Enter [*][8] [Installer Code].
2.
Enter [000] to go to Keypad Program-
ming.
3.
Enter Section [8].
4.
Enter the 2-digit PGM number (Do Not
enter the PGM Output Option).
4