CI10
EN
GETTING STARTED
RECOMMENDATION: CONFIGURE THE REMOTE CONTROLS BEFORE INS-
TALLING THE LOCK ON THE DOOR.
INSTALLING THE LOCK'S AERIAL AND BATTERIES:
• Install the aerial (P). Remove the cover off the lock box (A) by unscrewing
the gold-coloured screw on the side. Insert the batteries J (4 x AA) and the
emergency battery K (12V).
CONFIGURING THE REMOTE CONTROLSTO OPEN THE LOCK:
• Remove protective plastic from battery to activate controls.
• Place the remote controls near the
lock.
• Step 1: Use the Allen key (N) to press
the A register button on the lock twi-
ce in a row, hold the button down the
second time until you set the controls
(a beep will sound each time you press
the button).
• Step 2: Press button A on each control you want to link to the lock, pres-
sing it once (two beeps will sound when it has been linked).
In step 2, you can configure all the commands, if you press the A button on
each of them in a fast, consecutive way. Remember, hold down the A button
on the lock during the entire process.
If you let time to pass between one command and another, you must repeat
step 1 before configuring each com-
mand.
• Check that all controls work by ope-
ning and closing the lock.
CONFIGURING THE REMOTE CONTROLS
FOR EMERGENCY RELEASE:
Repeat the same process as mentio-
ned in the previous section but holding
down the lock's B register button and
also pressing the B button on the re-
mote controls.
6
USER INSTRUCTIONS
LOCK
Lock
To close the lock, press the (
you will hear 1 beep.
(A) Unlock
ATTENTION: when the batteries are running low, the lock will emit 4 beeps and
(B) Emergency release
will not lock.
OPEN NORMALLY
To open the lock, press A on the remote control. Once open, you will hear 2
beeps.
ATTENTION: when the batteries are running low, the lock will emit 5 beeps when
opening the lock. The batteries must be changed to ensure it operates correctly.
EMERGENCY RELEASE:
If the lock does not work by pressing A on the remote control (in case of dead
batteries), you must make an emergency release.
Activate the battery by hitting the door repeatedly (as if you were knocking
to enter) since the emergency battery remains inactive to avoid its depletion.
You will hear a beep. 2 seconds later, you must press B on the remote control.
The lock will open.
MANUAL OPENING OR USE OF THE LOCK AS A LATCH:
You can lock and unlock the bolts
by turning the manual opening
knob
direction.
ATTENTION: IN CASE OF A MIS-
PLACED REMOTE CONTROL
For security reasons, in case of a
lost remote control, all the com-
mands must be deconfigured and
the configuration process repea-
ted, so that the access code is modified, and the lost remote prevented from
being able to open the invisible lock.
RECONFIGURING THE REMOTE CONTROLS:
To erase the A opening codes of the remote controls, hold down the lock's A
register button (approximately 10 seconds) until a long beep sound. To clear
the B opening codes of the remote controls, hold down the lock's B register
button (approximately 10 seconds) until a long beep sound.
REPLACING BATTERIES
• When the lock's batteries are running low, it will emit audible beeps (See
instruction in "Lock" and "Opening").
TERIES ONCE A YEAR, TO ENSURE THE PRODUCT FUNCTIONS CORRECTLY.
HOW TO CHANGE THE BATTERY OF THE REMOTE CONTROL (1 X CR2032 3V)
RECOMMENDATIONS
• Measure the height at which the invisible lock has been installed, in case a
technical service has to carry out an emergency intervention. Measure the
distance from the floor to the bottom of the lock and memorise it (or record it
in your mobile phone's agenda, share it with a person you trust, etc.).
) button on the remote control. Once closed,
in
the
anti-clockwise
IT IS IMPORTANT TO CHANGE THE BAT-