Página 1
• Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D28409 Rev. 0 1/22/03...
SPECIFICATION CHART Model No. 919-167362 Max. Developed HP Bore 2.375" Stroke 1.35" Voltage-Single Phase 120V Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand.
Página 4
IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It Always operate the compressor in a well...
Página 5
HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use.
Página 6
HAZARD WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used properly Never operate compressor with it may cause electric shock.
Página 7
HAZARD WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
Página 8
HAZARD RISK OF UNSAFE OPERATION WARNING: WHAT CAN HAPPEN HOW TO PREVENT IT Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others.
GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
INSTALLATION HOW TO SET UP YOUR IMPORTANT: The outlet being used must be installed and grounded in UNIT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration as dry and well ventilated area.
Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the Parts Manual for the recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Certain air compressors can be and overheating.
OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Outlet Pressure Gauge On/Auto/Off...
Air Compressor Pump (not shown): How to Use Your Unit Compresses air into the air tank. How to Stop: Working air is not available until the compressor has raised the air tank Set the On/Auto/Off lever to pressure above that required at the "OFF".
Run the compressor for 15 Too much air pressure causes a minutes. Make sure the drain hazardous risk of bursting. Check valve is open and there is the manufacturer’s maximum minimal air pressure build-up in pressure rating for air tools and tank.
MAINTENANCE Customer Responsibilities Daily or Before after each each Check Safety Valve Drain Tank To Drain Tank Unit cycles automatically when Set the On/Auto/Off lever to power is on. When performing "OFF". maintenance, you may be exposed Pull the regulator knob out and to voltage sources, compressed air, or moving parts.
SERVICE AND ADJUSTMENTS Unit cycles Make sure the valve disc moves automatically when freely inside the check valve and power is on. When doing the spring holds the disc in the Maintenance, you may be exposed upper, closed position. The to voltage sources, compressed air check valve may be cleaned with or moving parts.
Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section. Unplug unit. Regulator Remove the outlet pressure gauge and quick connect (if equipped) from the regulator. Remove the regulator.
STORAGE Before you store the air compressor, Water will make sure you do the following: condense in the air tank. If not drained, water will Review the "Maintenance" corrode and weaken the air tank section on the preceding pages causing a risk of air tank rupture. and perform scheduled maintenance as necessary.
TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
Página 20
PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
Página 21
PROBLEM CAUSE CORRECTION Motor will not Fuse blown, circuit breaker Check fuse box for blown run. tripped. fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
AIR COMPRESSOR DIAGRAM Air Compressor Model Number 919.167362 Torque 50-60 in.-lbs. Torque 9-12 ft.-lbs. Torque Snug Torque 60-75 in.-lbs. Torque Snug 22- ENG D28409...
PARTS LIST Air Compressor Model Number 919.167362 PART NUMBER DESCRIPTION Pump Assembly Z-D26200 Tank AC-0396 Shroud, Rear CAC-1121 Shroud Bracket (used 2) SS-655-ZN Hex Nut 1/4-20 UNC (2used) SSN-60-ZN Washer (2 used) ACG-18 Saddle Mount Cup 91895680 Screw 1/4 - 20 x .75 (5 used)
PUMP DIAGRAM Air Compressor Model Number 919.167362 79-4 79-3 79-2 24- ENG D28409...
Página 25
PARTS LIST Air Compressor Model Number 919.167362 PART NUMBER DESCRIPTION Z-D27642 Motor SSF-615 Screw 1/4-20 UNC SST-3025-1 Bearing AC-0108 SSF-586 Screw 1/4-20 UNC x .75 >x 78 --------- Cylinder Sleeve > 79 --------- Connecting Rod Assembly >x 79-2 AC-0208 Formed Compression Ring >...
CUADRO DE ESPECIFICACIONES Modelo Nº 919-167362 Máx. HP desarrollado Diámetro interior 2,375 po (60,4mm) Carrera 1,35 po (34,3mm) Tensión monofásica 120V Circuito mínimo requerido Tipo de fusible Acción retardada Capacidad de aire en el tanque 4 Galones (113,6 litros) Presión de corte de entrada Presión de corte de salida SCFM a 40 psig 8,0 Calibre de libras...
INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES LA OPERACIÓN O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRÍAN OCASIONAR SERIAS LESIONES Y DAÑOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ...
Página 29
PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PODRÍAN, CAUSAR EL DEBILITAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSIÓN VIOLENTA, DAÑOS A LA PROPIEDAD O SERIAS LESIONES. ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamente o después de en el tanque, siendo la causa del óxido cada uso.
PELIGRO ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Su compresor de aire está accionado por Jamás opere el compresor a la intemperie electricidad. Como cualquier otro dispositivo cuando está lloviendo o en condiciones de eléctrico impulsado eléctricamente, si no se lo humedad.
PELIGRO ADVERTENCIA: RIESGO DE QUEMADURAS ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Jamás toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente después del compresor o los tubos de salida del escape, de la operación.
Página 32
PELIGRO ADVERTENCIA: RIESGO DE OPERACIÓN INSEGURA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? La operacion insegura de su compresor de aire Revise y comprenda todas las instrucciones y podría ocasionarle serias lesiones o la muerte advertencias contenidas en este manual. a usted u otros. Familiarícese con los métodos de operación y control del compresor de aire.
GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
INSTALACIÓN CÓMO PREPARAR LA UNIDAD Asegúrese de que el tomacorriente que será utilizado tenga la misma configuración que el enchufe de Ubicación del compresor de aire conexión a tierra. NO UTILICE UN Ubique al compresor de aire en una zona ADAPTADOR.
Página 35
Cables de extensión eléctrica Protección del voltaje y del circuito No se recomienda la utilización de cables Acerca del voltaje y la mínima cantidad de de extensión eléctrica. El uso de cables circuitos requeridos, refiérase al Manual de extensión eléctrica originará una caída de piezas.
OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
Bomba de compresión del aire (no Cómo utilizar su unidad mostrada): Comprime el aire dentro del Cómo detenerla: tanque. El aire de trabajo no se encuentra disponible hasta que el compresor haya Coloque la posición de la llave alcanzado a llenar el tanque hasta un nivel interruptora On/Auto/Off en la de presión por encima del requerido para posición "OFF".
Página 38
Luego de 15 minutos, cierre la válvula de Demasiada drenaje (sentido horario). El aire recibido presión de aire irá llenando hasta el punto de "corte" de podrá ser la causa de riesgo de explosión. presión, y el motor se detendrá. Verifique los valores de máxima presión dados por el fabricante de las herramientas El compresor estará...
MANTENIMIENTO Responsabilidades del cliente Antes Diariamente o luego de cada cada uso Verifique la válvula de seguridad Drenaje del tanque Cuando se Cómo drenar el tanque realizan Coloque la palanca On/Auto/Off en trabajos de mantenimiento, usted la posición "OFF". puede estar expuesto a fuentes de Tire de la perilla del regulador y gire voltaje, aire comprimido o piezas en en sentido contrario a las agujas de...
SERVICIO Y AJUSTES La unidad cicla Desenrosque la válvula reguladora (gire automáticamente en sentido antihorario) utilizando una en cuanto la energía eléctrica es llave tubular. conectada. Al efectuar el Asegúrese que el disco de la válvula se mantenimiento, usted quedará mueva libremente dentro de la válvula expuesto a tensión viva, aire comprimido o partes en movimiento.
Página 41
Ensamble el regulador y oriéntelo de Para reemplazar el regulador acuerdo a lo mostrado Libere toda la presión del aire del tanque. Vea "Drenaje del tanque" en la sección "Mantenimiento". Desenchufe el equipo. Regulador Usando una llave de tuercas ajustable retire el medidor de salida de presión y la conexión rápida del regulador (si la tiene).
ALMACENAJE El agua se Antes de guardar su compresor de aire, condensa dentro asegúrese de hacer lo siguiente: del tanque de aire. Si no se drena, ella Revise la sección "Mantenimiento" corroerá debilitando la paredes del de las páginas precedentes y ejecute tanque de aire, originando un riesgo de el mantenimiento programado de ruptura de sus paredes.
GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de intentar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
Página 44
CORRECCIÓN CAUSA PROBLEMA Si hubiese una caída excesiva de Es normal que ocurra algún La lectura de la presión durante el uso del descenso en la presión. presión sobre un accesorio, ajuste el regulador de manómetro (si acuerdo a las instrucciones de la viene equipado sección Operación.
Página 45
PROBLEMA CAUSA CORRECCIÓN El motor no Verifique la caja de fusibles observando Fusible fundido; interruptor funciona. automático del circuito disparado. la existencia de fusibles fundidos y sustitúyalos en caso de necesidad. Restablezca el interruptor automático. No use un fusible o interruptorautomático con valores que excedan los especificados para la rama de su circuito.
Página 48
Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.