Idiomas disponibles

Idiomas disponibles

Hold coupling
n ut and regulator
as shown for proper
connection
to LP tank valve.
Leak Testing Valves, Hose and Regulator
],
2.
3.
Turn all grill control knobs to OFF.
Be sure regulator is tightly connected to LPtank.
Completely open LPtank valve by turning OPD hand wheel
counterclockwise. If you hear a rushing sound, turn gas off
immediately. There is a maior leak at the connection. Correct
before proceeding by calling Sears for replacement parts at
1-800-4-MY-HOME ®.
4. Brushsoapy solution onto areas where bubbles are shown in
picture below:
6. Turnthe coupling nut clockwise and tighten to a fuji stop. The
regulator will seal on the back-check feature in the LPtank
valve, resulting in some resistance. An additional one-half to
three-quarters turn is required to complete the connection.
Tighten by hand only - do not use tool
NOTE:
If you cannot complete the connection, disconnect regulator and
repeat steps 5 and 6. if you are still unable to complete the
connection, do not use this reguJatod
CaJJ1-800-4-MY-HOME®
for an identical replacement parL
Never remove threaded
orifice at end of valve.
\
• Do not insert any tool or foreign object into the valve
outlet or safety relief valve. You may damage the valve
and cause a leak. Leaking propane may result in
explosion, fire, severe personal injury, or death.
5. If 'growing" bubbles appear, there is a leak. Close LPtank
valve immediately and retighten connections. Jfleaks cannot be
stopped do not try to repair. CaJJfor replacement parts at
1-800-4-MY-HOME ®.
6. Always close LPtank valve after performing leak test by turning
hand wheel clockwise.
• Outdoor gas appliance is not intended to be installed
in or on a boat.
• Outdoor gas appliance is not intended to be installed
in or on an RV.
° Never attempt to attach this grill to the self-contained
LPgas system of a camper trailer or motor home.
• Do not use grill until leak-tested.
" Jfa leak is detected at any time, STOP and caJJ
the fire department.
• Jfyou cannot stop a gas leak, immediately dose LP
cylinder valve and call LPgas supplier or your fire
department!
6 _ 23671m46477279
wAo°,°o
CARBON
MONOXIDE
HAZARD
• Burning charcoal
gives off carbon
monoxide,
which
has no odor and can cause death.
• DO NOT
burn charcoal
inside
homes,
vehicles,
tents, garages
or any enclosed
areas.
• Use only outdoors
where
it is well ventilated.
REV 2