Erreka AXIL Guía Rápida De Instalación Y Programación página 14

Ocultar thumbs Ver también para AXIL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1
Mount the wall bracket (1). An auxiliary plate can be
used if required (not included) (accessory AAX03 can
be ordered: rear fastening to the wall). Remove the
cap (2) and screw (3) and take off the cover (4).
2
3
Position the gate bracket (8) and weld it on. An
auxiliary plate can be used if required (not included)
(accessory AAX02 can be ordered: front fastening to
the gate).
AAX02
5a Adjusting the stoppers (inward opening):
Opening stopper [TA]: open the gate completely
and fix the stopper [TA] in place.
Closing stopper (AAX01) optional: close the gate
completely and fix the stopper (AAX01) in place. The
AAX01 stopper reduces the effective run from 337 to
316mm.
TA
13mm
IMPORTANT: if the AAX01 stopper is installed, we
recommend installing the TC exterior closing stopper.
If the AAX01 stopper is not installed, TC is obligatory.
6
Carry out several opening and closing movements manually in order to check proper operation.
14
3
AAX03
4
8
AAX01
13mm
Assembly
2
Mount the operator on the wall bracket using the pin
(5) and the nut (7) with the intermediate washers (6),
as shown in the figure.
P198A
4
Mount the operator on the gate bracket using the pin
(10) and intermediate washer (9).
P198C
5b Adjusting the stoppers (outward opening):
Opening stopper [TA]: open the gate completely
and fix the stopper [TA] in place.
Closing stopper (AAX01) optional: close the gate
completely and fix the stopper (AAX01) in place. The
AAX01 stopper reduces the effective run from 337 to
316mm.
AAX01
13mm
P198G
IMPORTANT: if the AAX01 stopper is installed, we
recommend installing the TC exterior closing stopper.
If the AAX01 stopper is not installed, TC is obligatory.
5
6
7
9
10
TA
13mm
6
P198B
P198D
P198H

Publicidad

Tabla de contenido
loading

Tabla de contenido