PROBLEM
Machine will not start
No displays
Excessive vibration
Feeder(s) fail to
operate
Clogged Corn Feeder
chute
Clogged Flour
Spreader chute
FAULT DIAGNOSIS
CAUSE
No power
Stop/Start not
illuminated
Timer not set/reset
or timed out
24V supply failure
Drive belt too tight
Road Wheel loose
No power
Maladjusted feed
Maladjusted feed /
water flow rate
Maladjusted feed /
water flow rate
- 16 -
SOLUTION
1. Check supply fuse
2. Check 10A fuse in
Control Unit
Fit/Refit safety cover.
Reset timer or set timer
as per paragraph 10
Check 0.2A fuse in
Control Unit
Adjust Drive Belt as per
paragraph 9.4
Check that the Road
Wheel retaining disc is
fitted and that the
securing screw is tight
1. Check that the flexible
feeder cable is correctly
inserted into its socket
2. Adjust hopper height
to release pressure on
the belt
3. Adjust hopper slide
plate to allow free
rotation of the drive belt
Adjust hopper slide plate
and/or water flow until
condition desists
1. Adjust hopper slide
plate to decrease the
flow rate of the emery
flour powder
2. Adjust the water flow
rate until the condition
desists
3. Check the alignment
of the Flour Spreader in
relation to the Road
Wheel