Step 9: First connect the alarm in/out cables to
the alarm board (please refer to table 3&4 for
definitions). Secure the alarm board onto the
top of the brass pillar with screws.
Step 10: Replace the lid of the power box and
affix it tightly using the included screws.
Step 11: Plug in the unit.
Fuse Replacement
The fuse can be accessed via a panel near the
3-pronged power connector on the side of the
Power Box.
Use a screwdriver to pry
open the fuse panel as
shown.
Once the panel has been
removed, you will see
the currently installed
fuse next to a clasp with
a spare fuse.
If needed, you may replace a blown fuse with
the provided spare.
Reconnect the fuse panel when finished.
Specifications
Electrical
Power Source
DCS-80-5: AC 110-115 V @ 50-60 Hz
DCS-80-6: AC 220-230 V @ 50-60 Hz
Certified Limited Power Source
Output
AC 24 V (max AC 29 V), 3.0 A max.
Mechanical
Environment
Indoor / Outdoor
Dimensions (H x W x D)
187 x 147 x 76 mm (7.36 x 5.78 x 3 inches)
Mounting Area (H x W)
187 x 147 mm (7.36 x 7.16 inches)
Weight
2 kg
Enclosure Material
Impact Resistant Polycarbonate Non-metallic
Flammability Rating
UL 94V-1
Color
Light Gray
Cover Fasteners
4 Captive Screws
Environmental
Waterproof Standard
IP66
Operating Temperature
0 °C to 40 °C (32 °F to 104 °F)
Storage Temperature
-40 °C to 50 °C (-40 °F to 122 °F)
Relative Humidity
0 to 95% non-condensing
Regulatory Compliance
Safety
LVD EN 60950
EMC
FCC, CE, C-tick, VCCI Class A
D-Link DCS-80-5/6 Outdoor Power Box 5
D-Link DCS-80-5/6 Outdoor Power Box 5