Installation To Wood Stud Wall - peerless-AV SUA765PU Instalación Y Ensamblaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation to Wood Stud Wall

• When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the
wood studs are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8".
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder
is highly recommended.
Use a stud fi nder to locate the edges of the studs. Use of an edge-to-edge stud fi nder is highly recommended.
1
Based on their edges, draw a vertical line down each stud's center. Center of display mounting plate will be 9.26"
offset from center of outer mounting slot as shown in fi gure 1.1 or will be 6.94" offset from center of inner mounting
slot as shown in fi gure 1.2. Place wall arm (A) on wall as template, level, and mark the center of four mounting
holes. Top mounting slot will be 6.60" (168mm) above display mounting plate as shown in fi gure 1.1.
Drill four 5/32" dia. holes to a minimum depth of 2.5". Secure wall arm (A) to wall with four wood screws (C) as
shown in fi gure 1.2. NOTE: Be sure arrow is pointing up when mounting wall arm (A) to wall as shown in fi gure 1.1.
Level, then tighten all fasteners.
Insert eight fastener caps (H) into wall plate mounting holes.
fi g. 1.1
6.60"
(168mm)
fi g. 1.2
= CENTER OF DISPLAY
9.26"
(235mm)
6.94"
(176mm)
WARNING
DISPLAY
MOUNTING PLATE
H
A
4 of 29
C
ISSUED: 05-01-11 SHEET #: 095-9358-7 11-21-14

Publicidad

Tabla de contenido
loading

Tabla de contenido