7.2 Changing the battery

• the lithium battery pack must be replaced by the same type of pack
with the same technical characteristics, i.e. 2 x (3.6 V – 13 Ah).
• We advise you to use the DAiteM BatLi22 pack available in the catalogue
in order to guarantee individual safety and equipment reliability.
• Dispose of the waste lithium power pack in an appropriate recycling bin.
to change the battery:
1. send a disarm command,
2. switch the control panel to installation mode:
master code
3. remove the siren from the wall,
4. remove the faulty lithium power pack,
5. wait for 2 minutes before connecting the new lithium pack,
6. close the siren and put it back on its base,
7. switch the control panel to user mode:
installer code
8. test triggering.

8. Summary of parameters

Parameter description
Delayed sounding
upon intrusion
Sounding duration
Sounding level of
disarm/arm indications
Transfer of disarm/arm
indications
Indication of audible
signals and door bell
Validation of radio link
in installation mode
then
Parameter-setting
sequence
** 4 * siren n° * 3 * ?? **
** 4 * siren n° * 4 * ??? **
** 4 * siren n° * 11 * ? **
** 4 * siren n° * 12 * ? **
** 4 * siren n° * 13 * ? **
** 4 * siren n° * 15 * ? **
installer code
Factory
parameter
0: immediate
90 s
4: average
2: vocal
message
1: enabled
0: on one
of 2 bands
106
Li
Possible values
from 0 to 60 s
0: immediate
from 20 s to 180 s
from 1 to 8
0: disabled
1: sounding
2: vocal message
0: disabled
1: enabled
0: validation
on 1 of 2 bands
1: validation
on 2 bands