Protection System Armed Indication; Alarm In Armed Presence Mode Indication; Triggering By A Technical Alarm; Triggering Following A Communication Network Interruption - DAITEM SH402AX Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56

4.9 Protection system armed indication

When this function is enabled, the siren indicates that the system is armed either by issuing a
series of 4 beeps or the voice message "bip, bip, bip, bip, Protection active". This function
can be disabled.
siren n°
Factory setting: 2
4.10 Alarm indication in armed presence mode
The siren is factory-set to issue the vocal message "bip, bip, bip, bip, intrusion group X" in
case of intrusion. This function can be modified. To do this, enter:
siren n°
Factory setting: 3

4.11 Triggering by a technical alarm

To modify triggering caused by a technical alarm, enter:
siren n°
Factory setting: 1

4.12 Triggering following a communication network interruption

When this function is enabled, loud sounding can be triggered (except when parameter 26 is
set at 0).
siren n°
Factory setting: 0
0: disabled
1: quiet sounding ("bip, bip, bip, bip")
2: vocal message ("bip, bip, bip, bip, Protection active")
0: disabled
1: quiet sounding (4 beeps)
2: loud sounding (15 s)
3: vocal message ("bip, bip, bip, bip, Protection active")
0: disabled
1: enabled
0: disabled
1: loud sounding triggered if the system is totally armed
2: loud sounding triggered 24/24
99
GB

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido