5. taking care of Galileo
Procedure:
To replace the battery you need a coin or
the dedicated tool that came with Galileo
and a clean cloth.
! WarninG
- A leaking battery cap may lead to the
destruction of Galileo by water seeping in
or cause Galileo to switch off without prior
notice.
- Always open the battery compartment in a
dry and clean environment.
- Only open the battery compartment to
replace the battery.
1. Dry Galileo with a soft towel.
2. Unscrew the battery cap using a coin
or the dedicated tool.
3. Inspect the o-ring on the battery cap.
If you see traces of seeping water,
damages or defects on the o-ring, replace
the o-ring with an original UWATEC
replacement part (PN 06.202.693). The
o-ring is provided with the UWATEC
battery kit for Galileo (PN 06.202.872).
When replacing the o-ring, make sure
the new o-ring is in perfect condition
and well lubricated, and that the o-ring,
o-ring groove and sealing surfaces are
free of dust and dirt.
4. Remove the old battery and dispose of
it in an environmentally friendly way.
5. Check the polarity of the new battery.
Galileo can be damaged if you do not
insert the battery correctly. Insert the
battery so that the + side is pointing
out of the battery case.
6. Screw the battery cap back in place.
Turn the cap until it is flush with the
surface and the slot on the battery
cap is aligned with the mark on the
housing. Damage to Galileo due to
68
improper placement of the battery cap
is not covered by warranty.
7. Check Galileo by turning it on.
F
NOTE:
- After a dive, Galileo stores tissue
saturation data once an hour while
on the surface until it is completely
desaturated. If
battery while Galileo has remaining
desaturation time, the tissue data
will not be lost, but Galileo will
reference the last stored data set. As
a consequence, the data displayed
on the surface screen after the
battery change (desaturation time,
surface interval, no-fly time and
CNS O
) may be different from the
2
values displayed just prior to the
battery removal.
- After replacing the battery, you must
set the date and time.
5.2.2 Replacing the battery in the
Smart transmitter
! WarninG
We recommend having the battery of the
transmitter
replaced
SCUBAPRO UWATEC dealer. The change must
be made with particular care in order to
prevent water from seeping in. The warranty
does not cover damages due to an improper
placement of the battery.
For best results, use the transmitter battery
set PN 06.201.920, comprising a CR2450
battery and a 26.00 x 2.00 mm transmitter
cap o-ring.
you change the
by
an
authorized