ON and OFF
• To start the vacuum cleaner, connect the power cord into the
power outlet.
• Set the switch in the on position "I" (ON).
• To turn the vacuum off, set the switch in the off position "O"
(OFF), and disconnect the power cord from the power source.
CAUTION
• Always double-check the switch is in the off
position before connecting the power cord in the power
source.

Dry vacuuming

• Open the vacuum cleaner as indicated in page 5. Verify
the cartridge filter for dry vacuuming is properly fit.
• Otherwise put the container cap upside-down.
• Set the filter into the filter cage (A) as indicated in the
figure. Then set the motor cover back in place.
• Verify that the collection bag is in its place otherwise see
sheet 7, for installation.
WARNING
• Do not vacuum or work near toxic,
flammable or explosive materials as indicated in the Safety
Warnings in page 5.
• When dry vacuuming do not use the
CAUTION
foam filter for liquid vacuuming.
• When the vacuuming job is done empty the
container before storing the vacuum cleaner.
Liquid vacuuming
• Open the vacuum cleaner as indicated in page 5 to install
the foam filter for liquid vacuuming.
• Set the container cap upside-down.
• Remove the cartridge filter and set the foam filter in the
filter cage (A) as indicated in the image.
• Remove the dust-collecting pouch. Do
CAUTION
not use it when vacuuming liquids. Then set the motor
cover back in place.
WARNING
• Do not vacuum or work near toxic,
flammable or explosive materials as indicated in the Safety
Warnings in page 5.
CAUTION
• To vacuum liquids do not use the cloth
filter for dry vacuuming.
• When vacuuming liquids do not
CAUTION
immerse the full nozzle into the liquid. Leave some space
in the tip of the nozzle opening to allow airflow. The tool is
built with a float valve to stop the suction action when the
container reaches its maximum capacity. A speed increase
in the motor is noticed. When it occurs stop the machine,
disconnect the power cord from the power source; open
the vacuum cleaner and pour into a receptacle or gutter
the liquid stored in the container.
• When the vacuuming is finished open the drain to empty
the container. Clean and dry the inside of the container.
Remove the foam filter. Set the cartridge filter in place and
close the drain cap before storing the tool.
8
ENGLISH

Start up

Switch
Filter cap
A
A
To secure the filter in
place turn cap clockwise.
To remove the filter, turn
in the opposite direction.

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

12089

Tabla de contenido