Description Of The Instrument - Chauvin Arnoux Multimetrix CT 51 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Description of the instrument

Operating
instructions
Precautions for Use
Operating
instructions
Note
10
- Do not connect the tester to a powered cable.
- Do not test more than one cable at a time.
1 - Connect the secondary unit to one end of the cable to be tested and
the main unit to the other end.
For a measurement on a wired installation, we recommend detaching
the secondary unit from the main unit by sliding the main unit; to do so,
push gently as per the indications on the casing.
2 - Press the green button at the centre of the main unit.
3 - Read the result on the test LEDs and interpret them as per the
indications given in the paragraph entitled. Test LED on main unit.
On the RJ-45 connectors, the test is performed on 8 LEDs, or on 9 LEDs
if the instrument is fitted with a ground connection.
As RJ-11 connectors have 6 wires, the result is read on 6 LEDs.
At link 1394, the result is read on 7 LEDs.
As USB connectors have 4 wires + ground, the result is read on 5 LEDs.
The BNC connector is read on 2 LEDs.