3.1.3. Levelling
-Do not anchor the machine, simply put it on a flat and levelled surface. Position the 4 adjustable feet
supplied and found inside the machine, on the tray. A good levelled base is important for correct
operation.
Procedure:
-Adjust the 4 levelling feet to ensure the stability and horizontality of the machine, checking it on both
sides of the machine with a spirit level (see figure below). After levelling, fasten the nut of each
foot using a spanner.
-The maximum adjustment height at the height of the levelling feet is 25 mm.
3.2.
Electrical connection
Make sure that the characteristics of the available power supply correspond to those of your ironing
machine, as indicated on the identification plate, and that the cable cross-section and other line
accessories are able to supply the necessary power.
A circuit breaker and differential switch MUST be inserted between the wiring and the mains, and the
sensitivity of the differential switch must be 300mA. Higher sensitivity, for example 30mA, common in
domestic installations may cause operating anomalies in the machine.
Connect the three phases, neutral in the general switch and the protection cable to earth on the electrical
components panel according to the following table (section in mm2).
22