Technical Data; Power Requirements - Truper ROTO-3/8A4 Manual Del Usuario

500 w potencia , 3/8” broquero
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Code
Description
Chuck
Voltage
Frequency
Current
Power
Speed
Drill Capacity
Duty Cycle
Conductors
Insulating
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
Tools with double insulation and reinforced insulation are equipped
with a polarized plug (one prong is wider than the other). This plug will only fit in the
right way into a polarized outlet. If the plug cannot be introduced into the outlet, reverse
the plug. If it still doesn't fit, call a qualified electrician to install for you a polarized
outlet. Do not alter the plug in any way. Both insulation types eliminate the need of both
a grounded third power cord with three prongs or a grounded power connection.
WARNING
When using an extension cable, verify the gauge is enough for the
power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cable's length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are especially designed
for operating outdoors and reduce the risk of electric shock.
Drill: 3 000 RPM
30 minutes work per 15 minutes idle. Maximum 3 hours per day.
18 AWG x 2C with insulating temperature of 221 °F
Class II
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
ROTO-3/8A4
16736
Hammer drill
3/8"
127 V
60 Hz
4,7 A
0.6 Hp
Hammer drill: 48 000 Strokes/minute
Metal: 3/8" | Concrete: 3/8" | Wood: 3/4 "
IP Grade
Power Cord Grips used in this product: Type Y.
Tool Build Quality: Double insulation.
Thermal insulation on motor winding: Class E.
Extension gauge
from 6' to 49'
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
IP20
Authorized Service Center.
|
higher than 49'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

16736

Tabla de contenido