WIND sensor

4.1
1.1
The anemometer (ANEM4) detects wind speed, which the control unit compares with the threshold set through DIPs 1-2-3 (see table).
The control unit is only compatible with anemometers generating 4 pulses per rev.
ALARM ACTIVATED when
The detected speed is higher
than the set threshold (see table
at side).

TEMPERATURE sensor

4.2
1.1
The temperature sensor (NTC 10K/3435K) activates whenever there is danger of ice forming.
ALARM ACTIVATED when
The measured temperature is below 2 °C.
Activation/
ACTIVATION
(only if the sensor is
deactivation
connected)
of the
temperature
DEACTIVATION
sensor with P1
* The buzzer will make a beep each time the button is pressed.
Alarm priority
HIGH
What happens with ALARM ACTIVATED
The control unit tilts the pergola slats at 33% of full
opening. The control unit executes no command.
Alarm priority
MEDIUM
What happens with ALARM ACTIVATED
The control unit tilts the pergola slats to 66% of full opening. The
control unit only executes hold-to-run commands.
*
7x
*
7x
L2
ALARM NOT ACTIVE when
The sensor has detected a lower
speed than the set threshold for 60
seconds.
L2
P1
11
Factory setting
ACTIVATED
DIP1 DIP2 DIP3 Km/h
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Factory setting
DEACTIVATED
ALARM NOT ACTIVE when
The measured temperature is above 3 °C.
HOLD
(5 s)
continuous
sound
4 s
L2 flashes
/
once every 3 s
OFF
OFF
40
OFF
ON
45
ON
OFF
50
ON
ON
55
OFF
OFF
60
OFF
ON
65
ON
OFF
70
ON
ON
75
t
°