Cooling Operation; Dehumidifying Operation - Royal Sovereign ARP-7120 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Temperature Settings: Celsius to Fahrenheit (or Fahrenheit to Celsius)
•∙To∙change∙Re.:∙press∙temp+∙and∙temp-∙simultaneously.

Cooling operation

•∙Press∙the∙"Mode"∙button∙till∙the∙"Cool"∙icon∙appears.∙
•∙Press∙the∙"Temp+"∙or∙"∙Temp-"∙button∙to∙select∙a∙desired∙room∙temperature.∙(62℉-90℉)
•∙Press∙the∙"Fan∙Speed"∙button∙to∙select∙wind∙speed.∙
Heating operation∙(this∙function∙is∙not∙available∙for∙a∙cold-single∙unit)∙
•∙Press∙the∙"Mode"∙button∙till∙the∙"Heat"∙icon∙appears.
•∙Press∙the"Temp+"or"∙Temp-"button∙to∙select∙a∙desired∙room∙temperature.(62℉ - 90℉)
•∙Press∙the∙"Fan∙Speed"∙button∙to∙select∙wind∙speed.∙

Dehumidifying operation

•∙Press∙the∙"Mode"∙button∙till∙the∙"Dehumidify∙Indicator∙Lamp"∙blinks.
Fan operation
•∙Press∙the∙"Mode"∙button∙till∙the∙"Fan"∙icon∙appears.∙
•∙Press∙the∙"Fan∙Speed"∙button∙to∙select∙wind∙speed.
Timer operation
Timer ON setting:
•∙When∙the∙air-conditioner∙is∙OFF,∙press∙the∙"Timer"∙button∙and∙select∙a∙desired∙ON∙time∙through∙the∙temperature∙and∙time∙setting∙buttons.∙
•∙"Preset∙ON∙Time"∙is∙displayed∙on∙the∙operation∙panel.∙
•∙ON∙timer∙can∙be∙set∙for∙any∙time∙from∙0∙to∙24∙hours.
Timer OFF setting
•∙When∙the∙air-conditioner∙ON,∙press∙"Timer"∙button∙and∙select∙a∙desired∙OFF∙time∙through∙the∙temperature∙and∙time∙setting∙buttons.∙
•∙"Preset∙OFF∙Time"∙is∙displayed∙on∙the∙operation∙panel.
•∙OFF∙timer∙can∙be∙set∙for∙any∙time∙from∙0∙to∙24∙hours.
Drainage Internal Tank Water Full Alarm Function
The inner water tank in the air conditioner has one water level safety switch, it controls water level. When the water level reaches an anticipated height, the water full
indicator∙lamp∙lights∙up.∙(If∙water∙pump∙is∙damaged,∙when∙the∙water∙is∙full,∙please∙remove∙the∙rubber∙drain∙plug∙at∙the∙bottom∙of∙unit,∙and∙all∙water∙will∙drain∙outside.)
Continuous Drainge
•∙∙ ∙ W hen∙you∙plan∙to∙leave∙this∙unit∙unused∙for∙a∙long∙time,∙please∙remove∙the∙rubber∙drain∙plug∙from∙the∙drainage∙hole∙at∙the∙bottom∙of∙unit,∙and∙connect∙a∙drain∙hose∙
to∙the∙lower∙fixing∙clip.∙All∙the∙water∙in∙the∙water∙tank∙will∙drain∙outside.∙
•∙If∙water∙pump∙is∙damaged,∙continuous∙drainage∙can∙be∙used,∙and∙under∙this∙condition,∙the∙water∙pump∙is∙not∙activated.∙The∙unit∙can∙also∙work∙well.∙
•∙∙ ∙ I f∙water∙pump∙is∙damaged,∙intermittent∙drainage∙can∙also∙be∙used.∙Under∙this∙condition,∙when∙the∙water∙full∙indicator∙lamp∙lights∙up,∙please∙connect∙a∙drain∙hose∙to∙
the∙lower∙fixing∙clip,∙then∙all∙the∙water∙in∙the∙water∙tank∙will∙drain∙outside.∙The∙unit∙can∙also∙work∙well.∙
8

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Arp-7120h

Tabla de contenido