ENGLISH
SET WARM-UP LEVELS:
 Press the FNC-button until the display shows a "3 horizontal lines on top of each other" on the 2
By default all channels are set to 0% warm-up, in this case the display shows
 Press the FNC-button to choose the different channels: 1,2,3,4,5,6 or A (All)
 Use the ▲/▼-buttons to set the warm-up level (0% to 6%) for the selected channel(s).
Example:
 Press the DMX-button shortly to return to normal working mode.
SELECT DIM OR SWITCH FUNCTION:
 Press the FNC-button until the display shows a "d" or "S" on the last digit.
By default all channels are set to dimming, in this case the display shows
 Press the FNC-button shortly to choose the different channels: 1,2,3,4,5,6 or AL (All)
 Use the ▲/▼-buttons to select "S" (switch) or "d" (dim) for the selected channel(s).
Example1:
Example2:
 Press the DMX-button shortly to return to normal working mode.
SETUP FOR JAPANESE 1PHASE/3WIRE SYSTEM:
 Press the FNC-button until the display shows
 When connected to the Japanese 1phase/3wire system: use the ▲/▼-buttons to select
 When connected to the European 3phase/4wire system: use the ▲/▼-buttons to select
 Press the DMX-button shortly to return to normal working mode.
Remark: default setting is "3FAC" for European 3phase/4wire connection.
SETUP FOR CERTAIN DMX-CONTROLLERS:
Some DMX-controllers send out a DMX-signal that is not fully within specs.
If the BT-626 does not work with such controller, you can try to change the protocol control function on/off to
make things work properly.
 Press the FNC-button until the display shows
 Use the ▲/▼-buttons to toggle both options.
 Press the DMX-button to return to normal working mode.
MONITOR THE DIMMING VALUES
 Press the DIM-button: the display will show you all incoming DMX-values for the 6 channels.
 Press the DMX-button shortly to return to normal working mode. (returns automatically after 10minutes)
MONITOR THE TRIAC TEMPERATURE
 Press the TEMP-button: the display will show you the temperature of the TRIACs. (example:
 Press the DMX-button shortly to return to normal working mode.
Remark: cooling fan starts working when the temperature reaches 45°C.
SET OUTPUTS MANUALLY
When no external controller is connected, you can still adjust the outputs manually with the 6 faders. Easy
for stand-alone use in restaurants, shops, ... where no external controllers are needed.
Remark: the settings of these channel faders overrule the DMX or analog control signals from external
controllers: all channel faders must be down (closed) when the unit is used with an external controller.
BRITEQ
®
means that channel 1 is set to 6% warm-up.
means that channel 2 is set to dimmer mode.
means that channel 4 is set to dimmer mode.
or
or
5/30
OPERATION MANUAL
.
.
.
BT-626
nd
digit.
.
)