Configuration - Urmet 1783/69 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

]
LINE OUT outgoing BUS line

CONFIgURATION

ID: in a riser column it is possible to install 2 CCTV bus interfaces or one secondary call station and one
CCTV bus interface; the two devices must have different addresses (0 or 1).
B/S: The images coming from cameras connected to the interface can be seen by all the users (BROAD) or
assigned to users 0 and 1 of the column (SEL/AP) by means of the dip switch "SEL/AP TELECAMERA".
SEL/AP CAMERAS: by setting the "B/S" dip-switch to SEL/AP, it is possible to assign all the cameras to
the user 0 (AP0) or to the user 1 (AP1). The dip-switch number corresponds to the camera number (dip
number 1 = camera connected to A1, B1 terminal pins).
§
Cameras can be associated only to users with CODE 0 and 1; the other users can see cameras images
only if the "Broadcasting" function is enabled.
8
Address 0
Cameras are assigned
to users 0 and 1
Camera 1 is assigned to
the user 0
Camera 2 is assigned to
the user 0
Camera 3 is assigned to
the user 0
Camera 4 is assigned to
the user 0
Address 1
Broadcasting function:
all the users can see the
images coming from
cameras.
Camera 1 is assigned to
the user 1
Camera 2 is assigned to
the user 1
Camera 3 is assigned to
the user 1
Camera 4 is assigned to
the user 1
DS1783-003B

Publicidad

Tabla de contenido
loading

Tabla de contenido