Problemas conocidos
this address. (0x02/0x03) Target:
oqn.1986-03.com.sun:02:host-name-pd0-s11u3-30-sparc, TPGT: -1
@ WARNING: iscsi connection(5) login failed - Requested ITN does not exist at
this address. (0x02/0x03) Target:
oqn.1986-03.com.sun:02:host-name-pd0-s11u3-30-sparc, TPGT: -1
@ WARNING: Failed to configure iSCSI boot session
@ WARNING: Failed to get iscsi boot path
panic[cpu0]/thread=20012000: vfs_mountroot: cannot mount root
Warning - stack not written to the dumpbuf
000000002000fa00 genunix:main+1dc (208a1000, 20122e40, 202f6640, 0, 0, 1)
%l0-3: 0000000000000000 00000000203bdc00 0000000000000000 0000000010070800
%l4-7: 0000000020122c00 0000000010070800 0000000000000000 0000000000000000
Deferred dump not available.
skipping system dump - no dump device configured and deferred dump is
disabled
rebooting...
Resetting...
Solución alternativa: realice los siguientes pasos para borrar la variable
1. Borre
ok
2. Inicie el sistema operativo.
ok
La descripción de ILOM-8000-AF es confusa
(21265789)
Es posible que el asesor de gestión de fallos informe de manera incorrecta que un SP o SPM
SPP sea defectuoso debido a los errores de ECC.
Solución alternativa: Revise los logs y los rastros del SP para comprender le motivo del error
fault.chassis.device.sp
un software. No necesariamente tiene que ser un problema de hardware. Sustituya el SP solo
cuando sea necesario.
La congestión temporal en el servidor RPC POD
remoto puede provocar el bloqueo de
(21419864)
El problema afecta al servidor SPARC M7-16 solamente.
28
Notas del producto de los servidores serie SPARC M7 • Marzo de 2017
en la petición de datos
os-root-device
set-default os-root-device
boot
. Es probable que el error sea de un componente de hardware o de
.
ok
stop /HOST
:
os-root-device