Motor With Resolver; Mechanical Installation; Troubleshooting - Festo EMMS-AS-190-S Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5

4.2 Motor with resolver

PIN 9 Motor, holding brake, temperature sensor
Power plug
U
Phase U
PE
Protective earth
W
Phase W
V
Phase V
1
Temperature sensor M
2
Temperature sensor M
+
Holding brake BR+
Holding brake BR–
1) Only for motors with holding brake EMMS-AS-...-ARB
Fig. 5
PIN aJ Resolver
Signal plug
1
R1 exciter signal +
2
R2 exciter signal –
3
S1 cosine signal +
4
S3 cosine signal –
5
S2 sine signal +
6
S4 sine signal –
Fig. 6

4.3 Mechanical installation

1. Clean the shaft of the motor 4.
The coupling will only grip without slipping on a shaft pin which is dry and free of
grease.
2. Push the slide or the cantilever of the driven mechanical components into a safe
position.
3. Connect the motor to the driven mechanical component by using the holes 3 on
the motor flange 5. Pre-assembled motor kits for linear drives can be found in
Festo's range of accessories (
4. Tighten the mounting screws (
doing this make sure that no axial force is exerted on the shaft of the motor.
5
Commissioning
Note
The motor can unexpectedly be started if the brake is released.
• Make sure that the motor windings are not energized before the brake is
released.
• Applycurrentfirsttotheholdingbrake.Thisallowsthemotortorotatefreely.
Dependingonthetypeofdevice,thecontrollerwillenergisetheholdingbrake
automatically.
• Complete the commissioning of the motor in conjunction with the controller in
accordance with the controller manual.
6
Operation
Warning
Hot parts of the housing can cause burning.
• Make sure that people and objects cannot come into direct contact with the
motor.
7
Maintenance and care
Warning
Layers of dust can catch fire.
• Clean the motor housing regularly.
8
Disassembly and repair
Warning
Masses which suddenly slide down may cause injury to people.
• Make sure that the effective load of the driven mechanical component is in a
safe position (e.g. in the case of a vertical installation: in the lower end posi-
tion).
• You can now remove the EMMS-AS from the mechanical component.
If repairs are required:
• return the motor to Festo.
Repairs by Festo will maintain the safety standards.
• Complete the fitting as follows:
1. Push the slide or the cantilever of the driven mechanical components into a safe
position.
2. Mount the EMMS-AS as described in the installation chapter.
(PTC)
T–
(PTC)
T+
1)
1)
Connection pattern
Accessories).
Instructions on drive and motor kits). When
9
Accessories
Note
• Please select the appropriate accessories from our catalogue
(
www.festo.com/catalogue).
10

Troubleshooting

Malfunction
Possible cause
Motor shaft does not turn
Load too high
Controller has not yet been
enabled
Holding brake active (only with
EMMS-AS-...-ASB/AMB/ARB)
Motor shaft rotates in the
Cabling fault
wrong direction or vibrates
Incorrect controller
parameters
Fig. 7
11
Technical data
General motor data
2
Output mass moment of inertia [kgcm
Product weight
[kg]
Radial shaft load
[N]
Axial shaft load
[N]
Insulation class according to EN 60034-1
Rating class according to EN 60034-1
Conforms to
Protection class (motor shaft)
Ambient temperature
[°C]
CE marking
Max. rel. air humidity
[%]
Operating voltage of encoder
[V DC]
Encoder current consumption
[mA]
Position values/U encoder (18 Bit)
Multi-turn encoder revolutions (12 Bit)
Resolver input voltage
[V]
Resolver input current
[mA]
Resolver transformation ratio
Number of poles of resolver
Resolver carrier frequency
[kHz]
Brake voltage (+6 ... –10 %)
[V]
Brake power
[W]
Brake holding torque
[Nm]
Specific motor data
Nominal voltage
[V DC]
Nominal current
[A]
Rated torque
[Nm]
Nominal speed
[rpm]
Rated output
[W]
Peak current
[A]
Peak torque
[Nm]
Max. speed
[rpm]
Motor constant
[Nm/A]
Winding resistance (25 °C)
[Ω]
Winding inductance (1 kHz)
[mH]
UL certification information
Product category code
Certificate number
Standards taken into account
UL test symbol
Fig. 8
12
Characteristic curves
Typical motor characteristics with nominal voltage and idealised controller.
Nominal voltage 565 V
HS Mmax
HS Mnenn
Fig. 9
Remedy
Reduce motor load
Check controller signal
Release holding brake
Check and correct the cabling
Check and correct controller
parameters
AS
ASB
AM
AMB
]
51.9
55.7
51.9
55.7
20.86
21.96
20.86
21.96
940
250
F
S1
IEC 60034
IP54 (IP65 for EMMS-AS-...-S1)
–10 ... +40
Declaration of conformity
90 (non-condensing)
5 ±5 %
≤160
≤190
262144
-
4096
-
-
-
-
-
-
24
-
24
-
17
-
17
-
30
-
30
HS
565
14.43
17.47
3000
5490
77.2
80
5300
1.211
0.283
3.07
PRHZ2 (USA) or PRHZ8 (Canada)
E342973
UL 1004, C22.2 No. 100-92
AR
ARB
52.1
55.7
21.10
22.20
–40 ... +40
-
-
-
-
4.0
20
0.5:1
2
3.4 ... 8.0
-
24
-
17
-
30

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Emms-as-40-m serieEmms-as-55-m serieEmms-as-190-m serie

Tabla de contenido