Technical Specifications - Orbis VIA Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

MANUAL OPERATION (THERMOSTAT)
If, when in START mode, the Comfort temperature regulation key is pressed for
more than four seconds, the equipment will enter THERMOSTAT operation
(without the timer), always controlling the Comfort temperature. To exit this mode,
the Comfort temperature regulation key must again be pressed for more than four
seconds.
RESET
REST must be pressed to rest the VIA timed thermostat and this will cause the loss
of the date, time and regulated temperature information.
KEYBOARD LOCKING
In order to prevent undesired manipulation, the keyboard can be locked in any
operating mode, by pressing without moving any of the side temperature regulation
controls for three seconds, with the locked keyboard indicator (a closed lock) being
shown onscreen. The same operation should be repeated to unlock the keyboard,
which will remove the locked indication.
When the keyboard is locked, the following is displayed onscreen
TELEPHONE CONTROL
The unit includes a specific connection for a telephone controller. When the
controller closes its circuit, the VIA changes to OFF mode and "off" is displayed
flashing onscreen, and it will return to the selected mode when the controller
contact is opened. When the telephone controller circuit is closed, the VIA unit
cannot be programmed.

TECHNICAL SPECIFICATIONS

Power supply:
Breaking power:
Battery lifetime:
Type of action:
Accepted programs:
Minimum programmable times:
Temperature measurement precision:
Temperature measurement resolution:
Temperature measurement and regulation:
Temperature regulation type:
Operation precision:
Temperature updating:
Output relay updating:
Battery replacement time:
Operating temperature:
Transport and storage temperature
Protection type:
Protection class:
Contamination situation:
Transient pulse voltage
Ball test temperature
Software class and structure
Connection
07/03.2013
Two 1.5 V LR03/AAA batteries
5(1) A /250 V~
Approximately one year
1B, 1S, 1T and 1U
8
60 minutes
± 0.5 ºC
0.1 ºC
From 5 ºC to 35 ºC
with setting of 0,5 ºC
Savings from +5 ºC to +25 ºC
Comfort from +15 ºC to +35 ºC
Anti-icing 4 ºC
ON-OFF with 0.2 ºC hysteresis
±1.2 s /24 h at 23 ºC
Every 60 seconds
Every 60 seconds
10 minutes
From 0 ºC to +50 ºC
From -10 ºC a +60 ºC
IP40 in accordance with EN 60529
II in correctly installed
2
2.5 kV
+ 80 ºC for 21.2.5
Class A
Terminals for wires of maximum
2
1,5 mm
section
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61
Teléfono:+ 34 91 5672277;
DIMENSIONS
E–28020 MADRID
Fax:+34 91 5714006
E-mail: info@ orbis.es
http://www.orbis.es
126,7
11.5
30
26
17
4
INSTALLATION DIMENSIONS
27,6
A016.73.53506