RELEASE INSTRUCTIONS
In the event of a breakdown or loss of voltage, insert the key
anticlockwise and rotate it, then open the hatch completely. Open
the barrier manually.
To reblock the barrier, close the hatch, turn the key clockwise
and remove the key.
Warning: do not release with the springs under tension
without rod. Carry out the rod blocking and unblocking
operations with the motor switched off. Do not enter the working
range of the rod. With the barrier unblocked, the rod may make
autonomous movements.
When the hatch is closed but the key is still horizontal, the release
microswitch is open and all manoeuvres are prevented.
(Only QIK7EH) to disconnect the barrier, you must cut off the
power supply and disconnect the batteries (if used).
GENERAL SAFETY PRECAUTIONS
The following precautions are an integral and essential
part of the product and must be supplied to the user.
Read them carefully as they contain important indications for
the safe installation, use and maintenace. These instruction
must be kept and forwarded to all possible future user of the
system. This product must be used only for that which it has
been expressely designed. Any other use is to be considered
improper and therefore dangerous. The manufacturer cannot
be held responsible for possible damage caused by improper,
erroneous or unresonable use. Avoid operating in the proximity
of the hinges or moving mechanical parts. Do not enter the field
of action of the motorised door or gate while in motion. Do not
obstruct the motion of the motorised door or gate as this may
cause a situation of danger. Do not lean against or hang on to
the barrier when it is moving. Do not allow children to play or
stay within the field of action of the motorised door or gate. Keep
remote control or any other control devices out of the reach of
children, in order to avoid possible involuntary activation of the
motorised door or gate. In case of breack down or malfunctioning
of the product, disconnect from mains, do not attempt to repair
or intervene directly and contact only qualified personnel. Failure
to comply with the above may create a situation of danger. All
cleaning, maintenance or repair work must be carried out by
qualified personnel.
In order to guarantee that the system works efficiently and
correctly it is indispensable to comply with the manufacturer's
indications thus having the periodic maintenance of the motori-
sed door or gate carried out by qualified personnel.
In particular regular checks are recommended in order to verify
that the safety devices are operating correctly. All installation,
maintenance and repair work must be documented and made
available to the user.