Installation Instructions
Please Read Before Installing
HWI-8SE-M Keypad
HWI-8SE-IR Keypad
Indicator LEDs
Button 6
Button 7
Button 8
Button 9
Button 23
HWI-4SE-M Keypad
HWI-4SE-IR Keypad
Indicator LEDs
Button 23
HWI-2SE Keypad
2
Button 1
Button 2
Button 3
Button 4
Button 5
(with or without
infrared receiver)
Button 24
Button 1
Button 2
Button 3
Button 4
Button 5
(with or without
infrared receiver)
Button 24
Button 3
Button 4
HWI-8SE-M
8 Scene Keypad with Master Control
HWI-8SE-IR
8 Scene Keypad with IR Receiver
HWI-4SE-M
4 Scene Keypad with Master Control
HWI-4SE-IR
4 Scene Keypad with IR Receiver
HWI-2SE
2 Scene Keypad
Description
The HWI-8SE-M, HWI-8SE-IR, HWI-4SE-M, HWI-4SE-IR,
and HWI-2SE keypads are for use with HomeWorks
Interactive
systems. The keypad buttons are programmed
TM
with a personal computer through your HomeWorks
Interactive processor using the HomeWorks Interactive
Utility. The HWI-8SE-IR and HWI-4SE-IR keypads have an
IR receiver which can be used for IR control. The IR
receiver accesses buttons 1-5, 23 and 24 using the GRX-IT
infrared transmitter, and buttons 1-9, 23 and 24 using the
GRX-8IT infrared transmitter. Button 5 does not have an
indicator LED.
Up to 32 keypads, each with a unique address, can be
connected to each keypad link on the HomeWorks
Interactive processor. A maximum of 300 keypad LEDs can
be connected per processor. To increase the number of
LEDs, see the HomeWorks Interactive Technical Reference
Guide.
Installation
Note: Keypad cannot be mounted in a U.S. style wallbox.
See Figure 6 for details.
1. Disconnect power to the keypads by turning off all
circuit breakers connected to the HomeWorks
Interactive Processor or keypad link auxiliary power
supply. Wiring with power ON may result in personal
injury and void warranty. Damage to this product
caused by wiring with power ON voids the warranty.
2. Address keypads. Assign a unique address to each
keypad using the DIP switch on the front of the keypad.
See Figure 3 (page 2) for DIP switch location. See
Figure 4 (page 3) for DIP switch settings. Be sure to
record the address for future programming purposes.
Do not change DIP switches 8 and 10. These
switches are set at the factory as shown in Figure
5.
3. Strip insulation from wires to 3/8" (10mm). Each
terminal will accept one or two 18-gauge (1.0mm
wires.
4. Connect wiring as shown in Figure 1 and 2 (page 3).
Note: The "shield" connection (position number 5) in
the terminal block is not used.
5. Mount keypad as shown in Figure 6 (page 4). Do not
over-tighten mounting screws. Some wallbox styles
use only two of the four mounting screws.
6. Restore power to the HomeWorks Interactive processor
and keypad link auxiliary power supply (if used).
®
2
)