Makita GSL02 Manual De Instrucciones página 36

Sierra de inglete inalámbrica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting for wireless activation function
Before asking for repairs, conduct your own inspection first. If you find a problem that is not explained in the manual,
do not attempt to dismantle the tool. Instead, ask Makita Authorized Service Centers, always using Makita replace-
ment parts for repairs.
State of abnormality
The wireless activation lamp does
not light/blink.
Cannot finish tool registration / can-
celling tool registration successfully.
The vacuum cleaner does not run
along with the switch operation of
the tool.
The vacuum cleaner runs while no
switches for the tool are in operation.
Probable cause (malfunction)
The wireless unit is not installed into the tool.
The wireless unit is improperly installed
into the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The wireless activation button on the
tool has not been pushed.
The stand-by switch on the vacuum
cleaner is not set to "AUTO".
No power supply
The wireless unit is not installed into the tool.
The wireless unit is improperly installed
into the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The stand-by switch on the vacuum
cleaner is not set to "AUTO".
No power supply
Incorrect operation
The tool and vacuum cleaner are away
from each other (out of the transmission
range).
Before finishing the tool registration/cancellation;
- the switch trigger on the tool is pulled or;
- the vacuuming button on the tool is
turned on or;
- the power button on the vacuum
cleaner is turned on.
The tool registration procedures for the
tool or vacuum cleaner have not finished.
Radio disturbance by other appliances
which generate high-intensity radio waves.
The wireless unit is not installed into the tool.
The wireless unit is improperly installed
into the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The wireless activation button on the
tool has not been pushed.
The stand-by switch on the vacuum
cleaner is not set to "AUTO".
More than 10 tools are registered to the
vacuum cleaner.
The vacuum cleaner has failed to
register tools successfully.
The vacuum cleaner erased all tool registrations. Perform the tool registration again.
No power supply
The tool and vacuum cleaner are away
from each other (out of the transmission
range).
Radio disturbance by other appliances
which generate high-intensity radio waves.
Other users are using the wireless activa-
tion of the vacuum cleaner with their tools.
36 ENGLISH
Remedy
Install the wireless unit correctly.
Gently wipe off dust and dirt on the terminal of the
wireless unit and clean the slot.
Push the wireless activation button on the tool
briefly.
Set the stand-by switch on the vacuum cleaner to
"AUTO".
Supply the power to the tool and the vacuum cleaner.
Install the wireless unit correctly.
Gently wipe off dust and dirt on the terminal of the
wireless unit and clean the slot.
Set the stand-by switch on the vacuum cleaner to
"AUTO".
Supply the power to the tool and the vacuum cleaner.
Push the wireless activation button briefly and perform
the tool registration/cancellation procedures again.
Get the tool and vacuum cleaner closer to each other.
The maximum transmission distance is approximately 10
m however it may vary according to the circumstances.
Push the wireless activation button briefly and
perform the tool registration/cancellation procedures
again.
Perform the tool registration procedures for both the
tool and the vacuum cleaner at the same timing.
Keep the tool and vacuum cleaner away from the appli-
ances such as Wi-Fi devices and microwave ovens.
Install the wireless unit correctly.
Gently wipe off dust and dirt on the terminal of the
wireless unit and clean the slot.
Push the wireless activation button briefly and make
sure that the wireless activation lamp is blinking in blue.
Set the stand-by switch on the vacuum cleaner to
"AUTO".
Perform the tool registration again.
If more than 10 tools are registered to the vacuum cleaner,
the tool registered earliest will be cancelled automatically.
Renew tool registrations.
Supply the power to the tool and the vacuum cleaner.
Get the tool and vacuum cleaner closer each other. The
maximum transmission distance is approximately 10 m
however it may vary according to the circumstances.
Keep the tool and vacuum cleaner away from the appli-
ances such as Wi-Fi devices and microwave ovens.
Turn off the wireless activation button of the other
tools or cancel the tool registration of the other tools.

Publicidad

Tabla de contenido
loading

Tabla de contenido