Installation
1. Place the system in the desired location. Ensure adequate
clearance so the the bypass valve can be operated when
necessary.
NOTICE
cal position. Do not lay it down during operation.
2. Connect the Hot Water supply to the inlet of the OneFlow
system. We recommend the use of the flexible Stainless
Steel connectors (not suppled with the system but available
from Watts). Observe standard plumbing practices and local
plumbing codes.
The OneFlow
NOTICE
mode which is opposite of a conventional softener. (The arrows
cast into the bypass valve are intended for a conventional soft-
ener and are, therefore, the OPPOSITE of the correct OneFlow
operating flow.)
3. Place the bypass valve in the SERVICE position (as shown
in Figure 1).
Media Replacement Procedure
Place the bypass valve in the BYPASS
position.
Dump the water and media into a
bucket. Pour off the water and discard
the media.
Place the tank on it's side. Install the
tank head and distributor into the
tank. Place the tank upright and hand
tighten until secure.
System must be operated in a verti-
system operates in the Upflow
®
Loosen the two hex screws and re-
move the valve from the head.
Pour the new media into the tank.
Return the tank to the service location.
Install the bypass valve onto the tank
head. Install and tighten the retaining
clips.
4. Place a bucket under the outlet port or run a line from the
outlet port to a drain.
5. Slowly open the supply valve (user supplied) to the
OneFlow
system. Allow the tank to fill with water. Close the
®
®
supply valve when a steady stream of water comes out of
the outlet port.
6. Connect the Outlet of the OneFlow
ing the appliance that requires pre-heated water.
7. Open the supply valve to the OneFlow
8. Operate the fill cycle on the attached equipment to clear the
line(s) of air bubbles.
®
9. Check for leaks. Repair as needed.
10. The system is now ready for service.
3
system to the line feed-
®
system.
®
Unscrew and remove the head from
the tank along with the pipe and
distributor.
O-ring
Lube the O-ring on the underside of
the tank head.
Slowly return the valve to the SERVICE
position.