In vertical position +/-15°.
far from an hot source in dry places at maximum temperature of 45°C and
minimum 0°C.
In a ventilated place and easily accessible by an operator for periodical
maintenance.
At a suitable height above the chemical up to a maximum height of 1.5
meters. If for exigency of the plant it's necessary to install the pump under
the level of the chemical, you need to use an injection valve or an anti
siphon valve.
Do not install the pump over the tank in presence of liquids that emanate
fumes unless it is hermetically closed.
2.2 Electrical characteristics
Power supply: 230 VAC 50/60 HZ
2.3 Electric connection
CAUTION !!!!!
Verify that the earth system is perfectly functional
and complies with the applicable regulations. Make
sure that the highly sensitive differential switch is
present (0.03 A). Verify that the rated values of the
pump are compatible with those of the mains. Never
install the pump directly in parallel with inductive
loads (e.g. motors/solenoid valves) if necessary, use
an isolating relay.
There are 2 protection devices inside the pump: a
varistor and a fuse.
The modular probe holder grounding must not be connected to the ground
cable of the panel but to an external ground node (fig. A)
2.4 Standard Kit
1
A POOL SYSTEM
2
Buffer Solution
3
Injection pipe
4
Discharge pipe
5
Suction pipe
6
pH Probe
9
Injection fitting x2
10
Foot filter x 2
Fitting MG ½" x 4
11
5' filter
12
2.5 Hydraulic Connection
ADSP7000474 A-POOL SYSTEM PH-CL
11/04/2014 Rev.1.9