3.2.4 Restore Parameters to Default values
3.2.5 Settings Alarm
With this sub-menu it is possible to set some protections for you Pool such as:
Stabilization time (1sec – 60 min) when the system is swithed on, it waits Stabilization
time before starting to dose (the probe readings need few minutes to be stabilized)
pH dosing alarm (5min – 60 min / OFF) if the pH pump doses its product and there is
no variation of pH (0.05 pH) during the set time, the system gives alarm and stop to
dose. The alarm is automatically disables near the set point (when the difference
between the measurement of pH and the set - point is less than 0.2 pH but only if the
pump is not dosing at maximum speed)
Cl dosing alarm (5min – 60 min / OFF) if the pH pump doses its product and there is
no variation of pH (0.05 ppm) during the set time, the system gives alarm and stop to
dose. The alarm is automatically disables near the set point (when the difference
between the measurement of Cl and the set - point is less than 0.2 ppm but only if the
pump is not dosing at maximum speed)
Pumps ON Alarm (5min – 60 min / OFF) if both the pumps doses for a period longer
than the set time the system gives alarm and stop to dose
Flow Control: the panel can be equipped with a flow-sensor, that detect the flow inside
the probe holder, if the flow is over the system gives alarm and stop to dose.
ADSP7000474 A-POOL SYSTEM PH-CL
It must be Activated for CONNECT version
11/04/2014 Rev.1.9
8/101