FAULT
Machine does not
Electric current
start, compressor
- No current delivered to connector of site panel (fuses)?
does not start and the
- No power delivered to machine
blue light is OFF
(defective connector connection? loose cable?)
- Main swiitch not turned on
The machine does not
Electric current
start but the compres-
(blu lamp on= main switch in correct position?)
sor starts no signal on
- Operating selector not in start position
display
- Hopper grid missing
- Plug not inserted correctly in socket
- Remote control connected?
- Spray jet nozzle dirty or clogged
- Supply voltage too high (over 250 volt)
The machine starts but
Material
stops immediately
- Material binding properties low
ERR03
(mortar pump seized?)
ERR04
- Material too dry
Material flow to the
Clogging
gun stops.
-Material hose clogged
A red light illuminates
- Spray jet clogged
on the electrical panel
- Low level of binder in mix
ERR03
- Sand not suitable for mix
ERR04
IMER INTERNATIONAL S.p.A.
IMER MORTAR MIXERS
CAUSE
26
CORRECTIVE ACTION
- Check points listed alongside
- Check points listed alongside
- Start unit up from remote control
- Clean nozzle with special cleaner
--Empty the hopper, ensure that the screw
is not blocked. when the machine is clean,
restart with liquid cement taking care to
mix the solution with at least 400/500 kg of
binder per cubic metre:
- Bring the density of the material equal to
that of a plastering mortar by adding water
- Work with lower flow rates
- Remove obstruction
- Connection to compressor detached
- Bodies in mix with too large section
- Use sand with constantly optimal particle
size curve.