ENGLISH
There is natural or artificial
air replacement in the room
which interfere the increase
of %RH.
The air inlet grids and nozzle
could be blocked.
The humidification
capacity is too low
Too much scale in the water
basin.
The humidity selected rate is
too low.
Water is too dirty or water
kept too long in the tank.
Humidifier is working in
Continuous mode.
The humidity target is too
high.
The ambient
Room is not well-ventilated
humidity is too high
Excess water tank has spilled
while filling the water tank or
replacing the water tank back
onto the base.
There is
The room temperature is too
condensation in the
low.
room
Programmed timer period
has run out.
The mist suddenly
The water shortage indicator
stops coming out
is on.
The target humidity level is
reached.
42
BREEZECARE 3000
Check if doors and windows are
closed.
Check if there is no air conditioning
working in the room.
Remove any blocking items from
the grids and the nozzle.
Clean transducer.
Increase mist output speed.
Increase humidity setting rate.
Clean water tank, change to fresh
clear water.
Change the mode.
Select a lower %RH target.
Open a window to ensure proper
air flow for the humidifier or move
the humidifier to a better ventilated
room.
Wipe off excess water from the
top and bottom of the base before
replacing the water tank.
Heat the room up.
Turn humidifier on.
Refill water tank.
Room is larger than the
effective range of the
humidifier.
Moisture has built up inside
of the humidity sensor.
Incorrect humidity
level is being
The nozzle is facing the
displayed.
direction of the humidity
sensor.
Humidity sensor is broken of
defective.
Hands are too wet when
operating control panel.
Control panel does
not work
Humidifier has
malfunctioned.
Water being used has a high
White dust
mineral content.
appears around the
humidifier
Humidifier was not properly
cleaned after last use.
Mist is coming out
Water tank is not positioned
from the base
correctly.
Mist fog coming out
There are apertures between
from around nozzle
the nozzle and water tank.
ENGLISH
Move the humidifier to a room
which is with suitable room size.
Turn off the humidifier and allow
the humidity sensor to completely
air dry before resuming use.
Turn the nozzle so that it is facing
away from the humidity sensor.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.
Keep hands dry while operating the
control panel.
Stop using the device immediately
and contact the Technical Support
Service of Cecotec.
Use distilled water with the
humidifier. If distilled water is not
available, use purified or filtered
water. Remember to clean water
tank at least once a week.
Clean humidifier.
Turn off and unplug the humidifier,
then align the water tank cover
with its respective opening in the
inner chamber.
Reinstall the cover and check if the
nozzle is well plugged in the cover.
BREEZECARE 3000
43