7.1
POSITIONING THE MODULE AND PULLEY
Table 3 indicates the measurements for the correct positioning
of the Module and Pulley on the beam for each type of
installation (Fig. 5a or Fig. 5b).
fi g.5a
Installing DOUBLE WING or RIGHT-SIDE SINGLE WING
A
fi g.5b
Installing LEFT-SIDE SINGLE WING
150
L
1100
L
11
-
-
L
A ; B
(mm)
(mm)
1800
300
2000
350
2400
450
2500
475
2800
550
3000
600
3200
650
3600
750
4000
850
4400
950
4800
1050
5400
1200
6000
1350
L = LENGTH of the automation WITHOUT FLANGES
A = SECURING DISTANCE of the IDLE PULLEY from the
END OF THE BEAM
B = DISTANCE of the MOTOR from the END OF THE
BEAM
1100
150
B
tab.3
150