Descargar Imprimir esta página

Lutron Grafik Eye PHPM-PA-DV-WH Instrucciones Para La Instalación página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

Mounting Methods
Mount to 2-gang U.S. wallbox
Mount to 4 x 4 in. (102 mm), 2.1 in. (53 mm)
deep U.S. junction box
Mount to 4 x 4 in. (102 mm), 2.1 in. (53 mm)
deep U.S. junction box with barrier (for 277 V
loads if required by local electrical code)
Barrier
R
Mounting Inside an Enclosure with
GRAFIK Eye Control Units
• Mount in accordance with all local and national
electrical codes.
• Proper ventilation is required. Ambient
temperature inside enclosure must remain
between 32 - 104 °F (0 - 40 °C) when GRAFIK
Eye control units and power modules are
operating.
• See diagram below for required spacing between
units.
Note! Plastic faceplate must be installed on
module for normal operation (all models).
GRAFIK Eye
Power
Module
LUTRON
4.5 in. (110 mm)
minimum
LUTRON
LUTRON
4.5 in. (110 mm)
minimum
LUTRON
LUTRON
LUTRON
GRAFIK Eye
Power Modules
®
5

Publicidad

loading