PW-100
PW-100
V5
V5
SETTING UP FUNCTIONS
Setting up HORN tone
The default tone is American HORN, although the equipment allows to choose between
American HORN and B&G HORN, as explained below.
1. Pull down and hold HORN.
2. While HORN is held down, pull up and
hold SIREN (3 s) until the tone changes.
m.WAIL
siren
inter
m.WAIL
HORN
aux/s
ptt
HORN
Setting up SIREN
SIREN function allows to choose among 4 different tones: WAIL, Hi-Lo, PHASER & YELP.
1. Pull up and hold SIREN (5 s) until the
2. Pull down HORN repeatedly to
siren sound briefly pauses. Release.
choose among tones.
m.WAIL
siren
inter
m.WAIL
HORN
aux/s
ptt
HORN
Setting up AUX
AUX allows to either play an auxiliary siren tone, or change the activation state of an
auxiliary load up to 15 Amp (useful to manage a light set or other devices).
1. Pull down and hold AUX (5 s).
2. Pull up SIREN to switch among AUX
Beeps once: it's set to AUX LOAD.
LOAD and AUX SIREN.
Siren stops & restarts: it's set to AUX
Beeps once: it's set to AUX LOAD.
SIREN.
Siren stops & restarts: it's set to
AUX SIREN.
m.WAIL
siren
inter
m.WAIL
HORN
aux/s
ptt
HORN
Setting up AUX SIREN tone
With AUX set to AUX SIREN, it is possible to select the AUX SIREN tone to one of the
available tones (WAIL, Hi-Lo, PHASER or YELP).
It is not possible to set the same tone for both SIREN and AUX SIREN, meaning that while
setting AUX SIREN, the SIREN tone in use will be unavailable; also, if the AUX SIREN tone
is selected for SIREN, AUX SIREN's tone will automatically change.
1. Pull down and hold AUX (5 s) until the
2. Pull down HORN repeatedly to
siren sound briefly pauses. Release.
switch among the available tones.
m.WAIL
siren
inter
m.WAIL
HORN
aux/s
ptt
HORN
Setting up AUX LOAD
With AUX set to AUX LOAD, it is possible to set AUX LOAD in a way that it gets activated
together with SIREN (for instance, that when SIREN sounds, a light set associated to AUX
LOAD turns on), in addition to the activation by pulling down AUX.
1. Pull down and hold AUX (5 s) until you
2. Pull down HORN to switch AUX LOAD mode.
hear 1 beep. Release.
Beeps once: it's set to independent.
Beeps twice: it turns on with SIREN.
m.WAIL
siren
inter
m.WAIL
HORN
aux/s
ptt
HORN
3. To change tone again, repeat steps 1
and 2.
siren
inter
aux/s
ptt
3. Pull up SIREN to fi nish setup.
siren
inter
m.WAIL
siren
aux/s
ptt
HORN
aux/s
3. Pull down AUX to fi nish setup.
It beeps twice upon fi nishing.
siren
inter
m.WAIL
siren
aux/s
ptt
HORN
aux/s
3. Pull down AUX to fi nish setup.
siren
inter
m.WAIL
siren
aux/s
ptt
HORN
aux/s
3. Pull down AUX to fi nish setup.
siren
inter
m.WAIL
siren
aux/s
ptt
HORN
aux/s
6
6
PW-100
PW-100
V5
V5
Setting the volume of the internal speaker, "internal volume"
1. While INTER is on, pull up and hold
INTER.
m.WAIL
siren
HORN
aux/s
Setting the volume of the external loudspeaker, "external volume"
1. Pull down and hold PTT.
m.WAIL
siren
HORN
aux/s
inter
External Volume Auto-Adjustment (VAA)
In addition to the manual adjustment, the equipment is capable of detecting the vehicle's
ptt
level of acoustic isolation and adjust the maximum external volume accordingly.
To perform this procedure, close all of the vehicle's doors and windows, and follow the
steps explained below.
To cancel the procedure, pull down PTT.
1. Pull down and hold PPT.
Remain silent during the procedure.
m.WAIL
siren
inter
HORN
aux/s
ptt
AUTOMATIC FEEDBACK CONTROL (AFC)
If acoustic feedback would occur while PTT or INTER are on (caused, for instance, by the
opening of a door or window), the equipment will detect and automatically fi x the issue
by decreasing the volume. After the event takes place, the equipment will attempt to rise
the volume back to the level defi ned by the user, as long as AFC is not triggered again.
ENERGY SAVING FEATURES (Automatic Shut Down, ASD)
Partial Shut Down (PSD)
The equipment continuously tracks the incoming voltage status. If the incoming voltage
is below 12.6VDC, after 20 seconds of inactivity the equipment activates PSD mode. This
inter
change is indicated by the turning off the switchbox lights. While on PSD mode, upon
pulling any switch the respective function will execute normally and the equipment will
ptt
return to normal energy consumption mode.
Total Shut Down (TSD)
If the incoming voltage is below 11.5 VDC, after 60 seconds the equipment will
automatically shut down any function and auxiliary load. While on TSD, upon pulling any
switch the lights will blink 3 times and the function controlled by the actuated switch will
not execute.
Once the equipment detects that the incoming voltage exceeds 12.5VDC again, the
equipment will return to its normal operation.
inter
ptt
2. While INTER is held up, pull up WAIL
to increase volume.
inter
m.WAIL
siren
inter
ptt
HORN
aux/s
ptt
2. While PTT is held down, pull up WAIL
to increase volume.
inter
m.WAIL
siren
inter
ptt
HORN
aux/s
ptt
2. While PTT is held down, pull down AUX.
Release both upon hearing a beep.
inter
m.WAIL
siren
inter
ptt
HORN
aux/s
ptt
7
7
3. While INTER is held up, pull down
HORN to decrease volume.
m.WAIL
siren
inter
HORN
aux/s
ptt
3. While PTT is held down, pull down
HORN to decrease volume.
m.WAIL
siren
inter
HORN
aux/s
ptt
3. Wait up to 30 s, the equipment will
beep 2 times when VAA has fi nalized.