WATER LINE CONNECTION
Connector Assembly
Ensamble del conector
"H" Clip
Sujetador tipo "H"
The bypass assembly connects to the water
system by means of a connector assembly. The
connector is secured to the plumbing and then
inserted into the bypass. A clip is used to hold it
in place.
Figure 10 Connector Assembly
Figura 10 Ensamble del conector
19 • 1/12
Drain Line
Línea de desagüe
IN
HACIA AFUERA
HACIA ADENTRO
Handles in Service
Manijas en posición de servicio
Figure 9 Series 360 Bypass Operation
Figura 9: funcionamiento normal de la derivación de la serie 360
IN
HACIA ADENTRO
OUT
Before inserting the connector:
• Check that all O-rings are in place and not
damaged.
• Lubricate O-rings and sliding surfaces with
100% silicone.
Firmly insert connector into bypass. Press
locking clip into position. Make certain the clip is
fully engaged.
To remove a clip:
1.
Turn off water and release water pressure
at the valve.
2.
Push the water line connectors into the
bypass and valve. This will help release
O-rings that may have seated in place.
3.
Remove the clip by inserting a flat blade
under the top center of the clip and lifting
(prying up).
CAUTION: Do not use pliers to remove a clip.
It is likely the clip will break.
NOTE: Before turning on the water to the valve,
rotate the two handles on the bypass valve 2-3
times. This will help seat O-rings and prevent
leaking.
OUT
HACIA AFUERA
Handles in Bypass
Manijas en posición de desvío