706 SERIES INITIAL POWER-UP
The water supply valve should be off or the
valve is in by-pass
Initial Power-Up - (Camshaft proceeds to
HOME position)
• At initial power-up, the camshaft may need
to rotate to the HOME (in service) position.
• Camshaft may take 1 to 2 minutes to return
to HOME position.
• Err 3 will be displayed until the camshaft
returns to HOME position.
• If more than 2 minutes elapses, verify that
the motor is turning the camshaft. If it is
not turning, check the "Troubleshooting"
section.
Figure 20 Initial Power-Up Display
Figura 20 Pantalla de puesta en marcha inicial
When the camshaft has reached the HOME
(service) position the display will show "- -:- -".
If the time of day alternating with capacity
remaining is displayed then the controller has
used short term memory to load settings.
INSTALLATION INSTRUCTIONS
STEP 1 PROGRAM TIME OF DAY
Press the Time of Day button. Press it again
within 5 seconds and the time will increment.
Press and hold for 2 seconds to rapidly
increment the setting. Release the button and
the time will be saved after 5 seconds.
35 • 1/12
Short term memory will hold settings for
approximately eight hours. Settings include:
• Water used today
• Water used since last recharge
• Current time of day
• Recharge state
Un-programmed controls will have the following
settings.
Default settings:
• Hardness - 25 grains per gallon
• Salt setting - HE, High efficiency
• System will recharge every 15 days
(calendar override) even if no water is
used. Unplug system for long periods of
no water usage. Calendar override is not
programmable.
In addition:
• Water used is set to 0
• The internal system clock is set to 8:00 AM.
The display continues to show "- -:- -" until
the time is manually set which updates the
internal clock.
• A recharge will initiate when the internal
system clock reaches 12:00 AM. The regen
Icon will flash.
Figure 21 Step 1
Figura 21 Paso 1