Zero and calibration of plate

1. The system has to be connected to the main power for at least 15 minutes before zero and plate
calibration can be done.
2. Set the selector in "Display" position.
3. Select the desired plate by a pressing on "No. of scale" button. On the display will appear
"Select plate".
4. Pressing on button "1" will select plate 1 (2 will select plate 2).
5. Make sure that the plate is empty.
6. Set the selector to the "Enter data" position.
7. Press on the "No. of scale" button, "Select scale" will appear on the display.
8. Press on "0" button. "Zero Calibration - Wait" will appear for a short time on the display and
then "Press enter to store" will appear.
9. Press the "Enter" button, the plate is zero calibrated.
10. Put a one-kilo weight on the center of the plate and press on the "No. of scale" button, "Select
scale" will appear on the display. If the unit has been programmed to work with pounds then
use a 2 pound weight. (see Change weight data from kilos to pounds)
11. Push on the "9" button, "1 kg Calibration - Wait" (in the pound program, "2 LB Calibration –
Wait") will appear for a short time on the display, then "Press enter to store" will appear.
12. Press the "Enter" button, the plate is calibrated.
13. Set the selector in "Display" position.
14. To calibrate other plates connected to the MS POULTRY WEIGHING COMPUTER, follow steps
3-13.
Important : The accuracy of the system depends on the accuracy of the one kilo load.

Start of a new round

Manual clearing of memory can be done on each plate separately.
1. Select the desired plate by a pressing on "No. of scale" button. On the display will appear
"Select plate".
2. Select the desired plate.
3. Set the selector to the "Enter Data" position.
4. Push on the "Uniformity" button; "Press enter to clear" will appear on the display.
5. Push on the "ENTER" button.
6. Return the selector to the "DISPLAY" position.
7. Adjust the start weight and day of growth (see "Enter start weight" and "Enter day of growth")
The unit is ready for operation.