System with CCTV interface Ref. 1783/69
TVCC
interface
Ref. 1783/69
2Voice
power supply
ADVANCED CONFIGURATION
In two-family systems with double call station, one station can be associated with user 0 and the other with
user 1:
•
Confi gure the two call stations as "single-family" (AUX dip 6 = OFF).
•
Confi gure the call station associated with user 0 as main (AUX dip 1 = OFF) and ID = 0.
•
Confi gure the call station associated with user 1 as secondary (AUX dip 1 = ON) with address 1 (AUX
dip 2 = ON) and ID = 0.
•
Position the rotary switch (CONV TIME) of the call station associated with user 1 to position "9". The
station emits a confi rmation tone.
•
On the call station associated with user 1, set the number of the door speaker unit ID = 1.
•
Change the position of AUX dip-switch no. 5 (the call module emits a confi rmation tone).
•
Set again the AUX dip-switch no. 5 in its previous position (the call module emits a confi rmation tone).
•
Set again the ID dip-switches in their previous position (ID = 0).
•
Exit from advanced confi guration, returning the rotary witch to the position for setting guaranteed
conversation time.
Example:
The main call station "A" calls only user 0 with both keys while the secondary call station "B" calls only user
1 with both keys.
•
On the call module "B" access to advanced confi guration;
•
Set the ID dip-switch to 1;
•
Move the AUX dip-switch no. 5;
•
Set again all the dip-switches in their previous position;
•
Exit from the advanced confi guration.
16
LINE 1
Calling station
LINE 2
ID = 0
Aux dip 1 = OFF (main)
2Voice
power supply
PROGRAMMING DATA DELETING
To delete all the data programmed in the advanced confi guration, follow the instructions below:
•
Go to advanced confi guration (CONV TIME = 9).
•
Holding down any key for at least 5 s, the door speaker unit emits a warning tone to confi rm
cancellation.
DOOR ELECTRIC LOCK MANAGEMENT
The door units have two terminals for managing the capacitance discharge and hold of the door electric lock
(SE-, SE+). The electric lock is operated in the following cases:
•
Whenever the hall button is pressed (terminals PA).
•
When is received a pedestrian crossing door lock release command coming from an apartment station,
according to the confi guration of the dip-switch AUX used to select operating mode "free" or "privacy"
(see "Confi guration" paragraph).
The electric lock activation time can be programmed by "Door Time" dip-switch.
GARAGE DOOR LOCK MANAGEMENT
The doors have two terminals connected to the contacts of a normally open relay which can be used to
control a gate opening control unit (1). The relay is operated for 1 s after receiving the garage door opening
command according to the operating mode ("free" or "privacy") as the door lock.
(1) The relay is not suitable to control direct power loads and can only be used as control relay. Refer to the
calling station manual for electrical features.
TECHNICAL SPECIFICATIONS
Power voltage (LINE): ..................................................................................................................... 36 – 48Vdc
Stand-by consumption: .................................................................................................................. 45mA max
Max. consumption (video call in progress and name tags on): .................................................... 250mA max
Working temperature range:.................................................................................................... -10°C ÷ + 50°C
Reference standards: ....................................................................................... EN 61000-6-3, EN 61000-6-1
DS1783-005
DS1783-005
Apartment station
User 1
CODE = 1
INT = 0
"B"
Apartment station
Calling station
User 0
ID = 0
CODE = 0
Aux dip 1 = ON (secondary)
INT = 0
Aux dip 2 = ON (station address 1)
Aux dip 6 = OFF (single-family)
LINE 1
Calls user 1
Calling station
ID = 0
Aux dip 1 = OFF (main)
Column interface
Aux dip 6 = OFF (single-family)
Ref. 1083/50
Calls user 0
ID = 0
"A"
17