GYS Smart Printer Module Manual De Uso página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
CONNECTION TO A GENERATOR
The machine can work with generators as long as the auxiliary power matches these requirements :
- The voltage must be AC, always set as specified, and the peak voltage below 400V,
- The frequency must be between 50 and 60 Hz.
It is imperative to check these values as many generators generate voltage spikes that can damage the machine.
INSTALLATION OF PAPER ROLL (CONSUMABLE REF. 056237)
To change the paper roll, open the printer cover with the lever (FIG 1 - 2). Position a new roll by pulling the 10 mm paper out of
the cover.
INTERFACE (MMI) (FIG-2)
4
Indicator
off
4
Indicator light
4
Indicator
fixed
Indicator
flashes quickly
5
(for 5 sec. maximum)
ANOMALIES, CAUSES AND REMEDIES
SYMPTOMS
Indicator
off
(host product running)
Indicator light
flashing slowly
Indicator
fixed
Indicator
flashes quickly wit-
hout interruption (for over 5 sec.)
The characters read by the
barcode reader do not match the
content of the barcode
CONFIGURATION OF THE BARCODE READER (ACCESSORY REF. 027718)
To work properly with the SPM, the barcode reader must be set to the default mode (USB, 9600b/s
baud rate). If in doubt, flash this barcode to reset it.
For a customised configuration of the barcode reader (alarm, volume, lowercase and uppercase characters, uppercase, etc.),
refer to the online barcode reader manual on the GYS website (ref. 027718).
SMART PRINTER MODULE
Product turned off
Power supply provided by the host product only
flashing
Power supply provided by the mains
(high printing speed and high current)
Product initialisation phase
SMC connection cable not properly connected or
damaged
Electronic problem on the card
Insufficient level or no paper
Thermal fault, the room temperature is too high
Incompatible USB device (mouse, USB key, etc.)
Excess power consumption on the USB port
Electronic problem in the printer
SPM not recognised by the host product
SMC connection cable not properly connected or
damaged
Electronic problem on the card
Incorrectly configured barcode reader
CAUSES
SOLUTIONS
Check the connection and status of the
SMC connection cable
Contact the reseller
Load a new roll of paper
Ventilate the room and allow the product
to cool down
Disconnect the device
Disconnect devices
Restart the host product
Contact the reseller
Verify that the SPM is an accessory sup-
ported by the host product
Update the software of the host product
Check the connection and status of the
SMC connection cable
Contact the reseller
Configure the barcode reader (see sec-
tion below)
Configure the host product
EN
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

026919

Tabla de contenido