7. CHECKS AND OPERATION OF THE MANUAL RELEASE (FIG 4)
After the installation, test the release system repeatedly: rotate the hollow hexagonal bolt (v6) clockwise by
means of the supplied wrench (K) until wings are released.
CAUTION ! The manual release must not be used when the mains or battery power supply is ON.
Incorrect use will permanently damage the electric lock.
F
F ig ig. 3
. 3
v6
X
8. FIRST ENTRANCE FUNCTION
A button for the First Entrance function is located inside the armoured box of the external manual release.
Electric connection (fig. 4)
Connect the First Entrance button with NO. contact between clamps No 10 (M/S COM) and No 12 (M/S IN)
of the automation control board.
WARNING ! Connect the wire terminal (X fi g 3) to a ground wire.
Use of the First entrance function
To operate the First Entrance function the Master Slave function must be disabled.
WING AND WING H150 AUTOMATIONS. The Master Slave function must be disabled on the WING control
board by setting DIP SWITCH No 3 on the programming card, or by setting the EC multifunction keypad
(see the relevant instruction manual).
WARNING ! If the Master Slave function is enabled, it is NOT possible to engage the First Entrance
function.
SLIM 702 AUTOMATION - The SLIM 702 control board does not include the Master Slave function. Then
no operation is required.
Operation
If the control board is set on the Night Lock the FIRST ENTRANCE function is enabled every time the relevant
button is pressed (button (B) if the connection is the same as in fig. 4).
The First Entrance function operates as follows: Night Lock.
F
F ig ig. 4
. 4
B
22
21
Automation CONTROL-BOARD
20
19
18
17
16
15
14
13
12
11
10
-
-
6
K
JP5