Operating Instructions

CONTINUOUS DRAIN

Water can be automatically drained from the unit by attaching a standard garden hose to the contin-
uous drainage port on the back of the unit. When the drain hose is connected, water collected by the
unit will bypass the water bucket and will drain directly through the hose.
Ensure the unit is on a level surface. If the unit is not level, water may bypass the drain hose and
collect in the water bucket.
Unscrew the cap on the back of the unit to access the garden hose nozzle.
Attach a garden hose onto the nozzle and lead it to a fl oor drain.
Cut the garden hose to ensure it is no longer than 1.8 m (6 feet).
Note: The thread standard for garden hoses is known as GHT or "garden hose thread" which has an
outer diameter of 27 mm (1 1/16 inches) and a pitch of 11.5 TPI or "threads per inch".
Ensure that there are no bends or knots in the drain hose as this can cause water to back up into the
water bucket.
Note: there is no drain pump in this unit, the drain is activated by gravity alone.
Note: the drain hose is not provided, it must be purchased separately.