Installation Instructions
LOCATION
•
Select a suitable location, ensuring there is easy access to an
electrical outlet.
•
Make sure there are no obstructions restricting airfl ow through the
front air intake grill.
•
Maintain a minimum clearance of at least 30 - 45 cm (12 - 18") on
all sides of the unit to allow for proper air circulation.
•
The unit should be operated in an enclosed area; keep all nearby doors and windows closed.
•
Place the unit on a smooth, level fl oor that is strong enough to support the unit with a full bucket of
water.
•
The unit has four rolling castor feet. Use care when moving the unit on carpet as the castors may
not be able to roll correctly.
•
Do not move the unit with water in the bucket; the unit may tip over and spill water.
•
Protect wood and carpet fl oors from spillage or scratches when moving unit.
•
The recommended operating ambient room temperature is between 5°C (41°F) and 32°C (90°F).
CASTOR INSTALLATION
The castors and power cord can be found inside the water bucket.
Fig. 1
•
Remove the bucket from the unit.
•
Remove the bucket cover.
•
Remove the castors and power
cord.
•
Replace the bucket cover.
•
Replace the bucket in the unit.
Fig 2.
•
Tilt the dehumidifi er 45°.
•
Push the castors into the bottom
of the unit until they click.
•
Ensure the ring around the castor
is fl ush against the bottom of the
unit.
Note: if the unit is placed on its
side or back, ensure that the unit
is allowed to stand upright and
undisturbed for a minimum of 4
hours before turning it on to allow
the coolant to settle.
Note: castors may already be in-
stalled on some models.
4