MOTOR CONFIGURATION: Identify the correct product application from the 3 given below and follow the relative configuration procedure.
Attention: if the wrong application is selected, the configuration procedure must be repeated for the correct application.
Pergola with 1 motor
2.1
1. MOTOR CONFIGURATION
DIP4=OFF
DIP5=OFF
=
P1
CLOSE
2. SELF-LEARNING OF LIMIT SWITCHES
< 1 s
+
P1
P2
Press P1 and P2 simultaneously twice in quick succession and
hold them the second time for 5 s
ON
DO NOT change the DIP configuration. This change would be signalled by a new intermittent sound and the flashing of L3, and would require a new configuration procedure.
1
2
3
4
5
6
(
5 s)
+
P1
P2
Press P1 and P2 simultaneously
and hold for 5 s
=
P2
OPEN
If the direction is wrong, invert the motor wires.