SW2
P1
SW1
6
7
8
Connector functions
5-pin CN1 connector: used for connection
to entry panel HEP/306 or HEP/312D.
3-pin CN3 connector: used for connection
to buttons KHPS or KHPD.
1-red: to button n° 2.
2-orange: to button n° 3.
3-yellow: to button n° 4.
WARNING. In installations with a number of
entry panels, call buttons must be arranged
in the same order on each.
Connector CN4: comes ready connected.
1-black: to button no. 1.
2-brown: to button no. 1.
3-green: to LEDs lighting the buttons.
4-yellow: to LEDs lighting the buttons.
5-pin CN5 connector: used for connection to
KHSO luminous warning kit.
Function of jumpers SW1 and SW2 (fig. 6)
SW1: automatic programming of number
of entry panels (default setting 1).
SW2: programming of receivers.
WARNING. Wires belonging to cables
that are not used must be insulated.
Programming of number of entry panels
(only required where there is more than one
entry panel)
1 - Start with the last entry panel connected
in series to the bus (usually the one with
terminals B IN not connected).
2 - Remove jumper SW1.
3 - Wait for the note confirming the opera-
tion (approximately 3÷15 s).
The number of confirmation signals also indi-
cates the number of present and programmed
entry panels (1 signal for the main entry panel
and 1 signal for each secondary entry panel).
4 - Refit jumper SW1.
Programming receivers
1 - Remove jumper SW2 from any entry
panel.
2 - Lift the handset of the receiver to be
programmed (for telephone sets, see the
instructions featured in interface IT/300).
3 - Press the door-lock release and auxiliary
2 buttons at the same time for at least 1
s (when audio towards the entry panel is
enabled, the operation is confirmed).
4 - On the entry panel, press the call button
the receiver is to be associated with.
5 - Replace the handset.
6 - Repeat the operation from point 2 on for
all remaining receivers.
7 - Refit jumper SW2 to exit programming.
WARNING. The programming procedure
for the VSE/301 selector, where fitted, must
only be performed once you have pro-
grammed which calls from the entry panels
are to be associated with which receivers.
In installations with XA/301LR we
recommend you gather up the receiver's
ID (SN) codes, applied on the outside
of the housing, and enter them in the
tables that come with the XA/301LR and
IPC/300LR.
NOTE. Once the power supplier has been
programmed using a PCS/300 unit, it will
no longer be possible to gain access to
the entry panel standard programming.
To restore default conditions, please
refer to the related chapter.
Return to default conditions from entry
panel
1 - Remove the SW1 jumper.
2 - Close the earthed door open contact.
A sound signal confirms that the operation
has occurred.
3 - Replace the SW1 jumper.
COLOUR VIDEO ENTRY PANEL HEVC/301
Video entry panel complete with colour CCD
camera and white-light LED for lighting the
target area.
Its features and functions are similar to those
of entry panel HEV/301.
Technical features
• Power supply: 14÷18 V DC.
• Current demand:
- on stand-by with 14V DC max. 230 mA;
- operating with 14V DC max. 380 mA;
- with door-lock release activated, add 500
mA;
- for each HEP/306-HEP/312D, add 35 mA;
- for each XDV/300A connected, add 40 mA;
- for 64 receivers, add 64 mA.
• Secrecy of speech/privacy of video signal.
• Door-lock release command: pulse-type for
solenoid lock at 12 V 1 A.
• Timed solenoid door-lock release: adjusta-
ble in the range 1 to 15 s.
• Installation activation time: 60 s.
• Call duration time: 30 s.
• Bus output: power supply at 15 V DC for
booster and receivers video driver balan-
ced type (Z = 100 Ω).
• Aux 1 command output: 3.5 V DC at 1 mA
(available only with entry panel enabled,
activation time same as timed solenoid
door-lock release).
• Aux 2 command output: 3.5 V DC at 1 mA
(always available in all entry panels, activa-
tion time same as timed solenoid door-lock
release).
• Entry panel activation output: 3.5 V DC
at 1 mA (enabled for entire duration of
conversation).
• Working temperature range: -15 °C to +50 °C.
Camera technical features of HEV/301
entry panel
• Video signal system: CCIR (EIA).
• Sensor: 1/4" CCD.
• Horizontal frequency: 15,625 Hz (15,750
Hz EIA).
• Vertical frequency: 50 Hz (60 Hz EIA).
• Video output: 1 Vpp composite to 75 Ω.
• Resolution: 380 lines.
• Minimum illumination: 5 lx.
• S/N ratio: 45 dB.
• Iris control: automatic electronic in the
range 1/50 s 1/100,000 s.
• Lens: fixed-focus f 3.7 F 4.5.
Camera technical features of HEVC/301
entry panel
• Video signal system: PAL.
• Sensor: 1/4" CCD.
• Horizontal frequency: 15,625 Hz.
• Vertical frequency: 50 Hz.
• Video output: 1 Vpp composite to 75 Ω.
• Resolution: 330 lines.
• Minimum illumination: 50 lx.
• S/N ratio: 46 dB.
• Iris control: automatic electronic.
• Lens: fixed-focus f 3.7 F 5 (pin-hole).
Installation instructions
The embedding box must be fitted flush
with the wall and at an height that ensure
optimal camera operation. Fit the spacer
into embedding boxes to avoid deformation
(fig. 1).
It is possible to use the screwdriver obtained
from the spacer to adjust the microphone
and speaker volume (fig. 4).
WARNING. Connecting cables must be
fed through one of the knockout cable
entry points, located at the bottom of the
embedding box (A in fig. 1).
Using the Allenkey s 2.5 supplied, unscrew the
lock screw and remove the front plate from
the chassis (fig. 2).
In order to fit additional buttons, follow the
instructions supplied with each.
Remove the two plugs protecting the threa-
ded holes in the embedding box and secure
the chassis using the two screws supplied
(fig. 3).
Perform the wiring. The name card can be
removed and filled in with the relevant infor-
mation by removing the card clip followed
by the actual card itself (fig. 7).
NOTE. Personalized name cards can be used
up to a maximum of 2 mm thick.
In order to fit the front plate, first insert the
upper part in the top moulding and then,
using a Allenkey s 2.5, tighten the lock screw
(fig. 8).
3

Publicidad

loading

Este manual también es adecuado para:

Hevc/301