During an adjustment session each parameter may be checked or changed at any time in the following way:
PARAMETER
USER'S ACTIONS
KEY
CHECK
Press the Key (5,6,7,8,11) corresponding to the parameter to be checked and then press the CHECK VALUES Key
VALUES
(9).
Count the number of times the green LED flashes, which correspond to the value of the checked parameter. No
green LED flash corresponds to the value 0.
Repeat this operation to check the value of the other parameters if required.
Example: SENSITIVITY Key (6) – 7 flashes of the green LED: the sensitivity is set at the value 7.
CHECK VALUES:
PLUS
Press the Key (5 or 6) corresponding to the hold time or sensitivity parameter to be modified
and then press the PLUS Key (2) to increase the value by 1 unit.
PLUS:
MINUS
Press the Key (5 or 6) corresponding to the hold time or sensitivity parameter to be modified.
and then press the MINUS Key (4) to reduce the value by 1 unit.
MINUS:
During a sensor adjustment session all the parameters may be reset to their factory values in the following way:
PARAMETER
USER'S ACTIONS
KEY
DEFAULT
Press the DEFAULT VALUES Key (12), then press the NUMBER Key 1. All the parameters are reset to the
VALUES
factory values (see below).
DEFAULTS VALUES:
PARAMETER KEY USER'S ACTIONS
SENSITIVITY
Press the SENSITIVITY Key (6).
Use the NUMBER Keys 0-9 (1) to enter the sensitivity
required (or adjust this sensitivity using the PLUS (2) or
MINUS (4) keys as explained above)
SENSITIVITY:
HOLD TIME
Press the HOLD TIME Key (5).
Use the NUMBER Keys 0-9 (1) to enter the required hold
time (0.5 s to 9 s) (or adjust this parameter using the PLUS
(2) or MINUS (4) keys as explained above).
HOLD TIME:
Press the RELAY CONFIGURATION Key (11).
RELAY
Use the NUMBER Keys 1-4 (1) to select the required relay
CONFIGURATION
configuration:
75.5351.02 EN 20080317 (75.5350)
X
X
X
1
0-9
0-9
FACTORY
LED SIGNAL
SETTING
7
The red LED flashes quickly
waiting for the value.
Once this has been entered, it
flashes slowly again.
0.5 s
The red LED flashes quickly
waiting for the value.
Once this has been entered, it
flashes slowly again.
1
The red LED flashes quickly
(Active
waiting for the value.
Output)
Once this has been entered, it
flashes slowly again.