WARNING! Keep this unit away of children! Never leave this device running unattended!
WARNING! Use only original Beamz foam fluid. Warranty will be voided if any other type of liquid is used, improper use of liquid may lead to
machine failure and malfunction.
Notes:
-
The foam cannon should work max. 30minutes continuously. After that the machine should be stopped for min. 15 minutes.
-
The pump's delivery height is determined by the operating mode (suck or push), the inner diameter of the hose and the degassing behaviour
of the fluid. In the supplied configuration, we recommend a maximum feed rate of 6 meter (19.5ft).
IMPORTANT BY END OF A SHOW
The fan must remain running for 15 minutes after the last foaming in order to dry the fan motor. Disconnect the unit from the mains supply before
disassembling. Always remember to close the water taps and hydrants. Frequent cleaning and service of generator, pump, tank and hoses will ensure
you a long lasting lifetime of our product.
CLEANING
We recommend a frequent cleaning of the unit. Please use a soft lint-free and moistened cloth. Never use alcohol or solvents!
CAUTION! There are no serviceable parts inside the unit except for the fuse. Repairs and service operations are only to be carried out by
authorized dealers.
WARNING! Disconnect from mains before starting maintenance operation!
REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
5