This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or
maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified Black&Decker
technician.
Problem
Motor does not start or does not restart
(Do not insist to start the motor. Do it only after
you have discovered and eliminated the cause
of the problem)
Code
1, 2, 3, 4, 5, 7, 14, 15, 22
Problem
Reduce air production
(Pressure gauge keeps showing a lower pressure
than that of the job)
Code
6, 8, 9, 10, 11, 13, 16
CAUSA POSSÍVEL
COD
1
Queda ou falta de tensão na
rede elétrica.
Problem
The compressor unit overheats
2
Motor elétrico danificado.
Code
5, 6, 10, 11, 12, 13, 16, 20, 25
3
Reservatório cheio de ar.
Problem
Electric motor overheats
Code
5, 7, 10
4
Fusível da instalação queimado.
Problem
Premature wear of the compressor unit
5
Válvula de retenção não veda
internal parts
devido a presença de impurezas.
Code
6, 9, 10, 12, 15, 16, 23
6
Demanda do sistema acima da
capacidade do compressor.
Problem
Abnormal noise or vibration
7
Protetor térmico atuou.
Code
15, 16, 17
Problem
Tank pressure increases quickly or too frequent
8
Filtro obstruído.
starts (The normal number of starts is roughly
9
Vazamento de ar no compressor.
6 an hour)
Code
19, 24
10
Temperatura ambiente elevada
(Máx. 40˚C).
POSSIBLE CAUSE
COD
11
Junta da placa de válvulas rompida.
1
Voltage drop or electrical
supply is out.
12
Óleo lubrificante incorreto
2
Damaged electric motor.
ou baixo nível de óleo.
3
Tank is full of air.
13
Carbonização da placa de válvula.
4
Installation fuse has burned out.
14
Rede elétrica subdimensionada
5
Check valve does not seal
ou deficiente.
because of impurities.
15
Operando em ambiente agressivo.
6
The demand is above
the compressor's capacity.
7
Thermal protector tripped.
16
Não foi efetuada a troca de óleo
no intervalo recomendado.
17
Elementos de fixação frouxos.
8
Filter clogged.
18
Vazamento contínuo de ar pela
9
Air leakage in the compressor.
válvula de alívio do pressostato
quando o compressor desliga.
10
High ambient temperature
(Max. 40˚C or 104˚F)
19
Excesso de água no reservatório.
11
Valve plate joint is broken.
20
Acúmulo de pó (tinta) sobre
12
Wrong oil or low oil level.
o compressor.
TROUBLESHOOTING GUIDE
SOLUÇÃO POSSÍVEL
Verifique a instalação e/ou
aguarde a estabilização da rede.
Procure o Centro de Serviço
Autorizado Black&Decker.
O motor elétrico partirá assim
que a pressão no reservatório
diminuir.
Localize a causa
(Veja Tabela 2 - Pág. 14)
Encaminhe o compressor ao
Centro de Servico Autorizado
Black&Decker.
Redimensione o compressor
se necessário.
Desligue o compressor, aguarde
5 (cinco). Se ocorrer reincidência
frequente procure o Centro de
Servico Autorizado Black&Decker.
Substitua-o.
Reaperte os parafusos e/ou
as conexões.
Melhore as condições
de instalação.
POSSIBLE SOLUTION
Procure o Centro de Serviço
Check the installation and/or wait
Autorizado Black&Decker.
for the electrical supply stabilization.
Utilize óleo lubrificante mineral
Send it to the nearest Black&Decker
conforme recomenda este manual,
Authorized Service Center.
ou verifique o nível e reponha
se necessário.
Electric motor will start
as soon as the pressure
Proceda a limpeza da mesma a
in the tank decreases.
cada 1000 horas de serviço ou
12 meses através do Centro de
Find out the burning cause
Serviço Autorizado Black&Decker.
(See Table 2 - Pág. 21)
Consulte um técnico especializado.
Send the compressor to the
nearest Black&Decker
Authorized Service Center
Proceda a troca dos componentes
através do Centro de Serviço
Check the compressor's capacity.
Autorizado Black&Decker.
Melhore as condições locais.
Turn compressor off, wait for 5 (five)
Proceda a troca dos componentes
min. and reset the protector. If tripping
através do Centro de Serviço
is frequent, look for the nearest
Autorizado Black&Decker.
Black&Decker Authorized Center.
Localize e reaperte.
Replace it.
Encaminhe o compressor ao
Re-fasten bolts and/or fittings.
Centro de Serviço Autorizado
Black&Decker.
Improve local conditions.
Drene o reservatório através do
purgador, conforme indicado
Look for the nearest Black&Decker
na Fig. B - Pág. 2
Authorized Center.
Limpe o compressor externamente.
Change oil.
Problem
High temperature of the compressed air
Code
5, 6, 8, 9, 10, 11, 12, 13, 20
Problem
Compressor operate ininterruptedly
Code
6, 8, 13, 25
Problem
Excessive consumption of lubricating oil
(Compressors usually use more oil in the first 200
working hours until rings are smoothly adjusted)
Code
6, 10, 12
POSSIBLE CAUSE
COD
1
Voltage drop or electrical
supply is out.
Problem
Lubricant oil with unusual color
2
Damaged electric motor.
Code
10, 15, 16, 21
3
Tank is full of air.
Problem
Insufficient pressure for required work
Code
15, 18, 24
4
Installation fuse has burned out.
Problem
Air leakage through relief valve of pressure switch
5
Check valve does not seal
or compressor unit (when assembled), with
because of impurities.
compressor operating from more than 1 (one)
6
The demand is above
minute (valve closes above 20 psi (1.3 bar))
the compressor's capacity.
Code
25
7
Thermal protector tripped.
8
Filter clogged.
9
Air leakage in the compressor.
10
High ambient temperature
(Max. 40˚C or 104˚F)
11
Valve plate joint is broken.
12
Wrong oil or low oil level.
13
Carbonized valve plate.
14
Deficient or inadequate
electrical supply.
15
Operating in a non-adequate
environment.
16
The oil change did not occur at
the recommended interval.
17
Loose fastening elements.
18
Continuous air leakage through
pressure switch's relief valve when
compressor shuts off.
19
Excess water in the tank.
20
Too much dust and paint
on the compressor.
21
Water is mixed with the oil
(milky coloration).
22
Ambient temperature below minimum
ENGLISH • 23
POSSIBLE SOLUTION
Check the installation and/or wait
for the electrical supply stabilization.
Send it to the nearest Black&Decker
Authorized Service Center.
Electric motor will start
as soon as the pressure
in the tank decreases.
Find out the burning cause
(See Table 2 - Pág. 21)
Send the compressor to the
nearest Black&Decker
Authorized Service Center
Check the compressor's capacity.
Turn compressor off, wait for 5 (five)
min. and reset the protector. If tripping
is frequent, look for the nearest
Black&Decker Authorized Center.
Replace it.
Re-fasten bolts and/or fittings.
Improve local conditions.
Look for the nearest Black&Decker
Authorized Center.
Change oil.
Clean it every 1000 working hours
or 12 months at your nearest
Black&Decker Autorized Service
Center.
Have a specialized technician
check it.
Improve local conditions.
See "Care and Maintenance"
Page 21
Find and re-fasten them.
Send compressor to the nearest
Black&Decker Authorized Center.
Drain the tank through the drain
as indicated in Fig. B - Page 2
Clean the compressor externally.
Change the lubricant oil and run
your pressure compressor for
15 min, at a maximum pressure of
100 psi (7.0 bar). This will remove
any internal condensation signs
inside pump.
Run the equipment above 5˚C